HP 16-port SCS Installation Instructions Manual page 63

Table of Contents

Advertisement

Table 5-11
Port Set command parameters
Parameter
STOP=<stopbits>
FLOW=<signal>
TIMEOUT=<time-out>
SOCKET=<socket>
CHAR=^<cli_char>
TOGGLE=NONE|DTR
POWER=<signal>
Description
Number of stop bits per character. Valid values are 1 and 2.
Default = 1
Flow control signal. For hardware flow control, be sure the control signals are correctly wired,
or data loss might occur. The flow control signal cannot also be used for power status
monitoring. Valid values are:
XONXOF—Software XON/XOFF flow control
RTSCTS—Hardware RTS/CTS flow control
DTRDCD—Hardware DTR/DCD flow control
None—No flow control
Default = None
Number of idle minutes, in the range 1 to 90, that the SCS will wait before dropping a
connection to the port. If the value is zero or omitted, the port will use the time-out value
specified in the Server CLI command. (To completely disable port time-outs, the time-out
values in the Port Set and Server CLI commands must be zero.)
The new value does not affect an active session; it takes effect in subsequent sessions.
Default = 0 (use value from Server CLI command)
TCP port that must be entered on the Telnet client to connect to this serial port. The new value
becomes effective in subsequent sessions.
When SSH is enabled, the SCS automatically adds 100 to the specified value.
When All is specified, port 1 will be assigned the specified socket value plus 1, port 2 will be
assigned the specified value plus 2, and so on. When All is specified and SSH is enabled,
port 1 will be assigned the specified socket value plus 101, port 2 will be assigned the
specified value plus 102, and so on.
When both plain text Telnet and SSH connections are enabled, the +100 value will not appear
in displays.
The value should not be in the range 6000 to 6063.
Default = 3000 plus the port number; 3100 plus the port number if SSH is enabled
CLI access character in the range A to _ (underscore) or None. (The allowable ASCII range is
0x41-0x5F and 0x61-0x7A.) The CLI access character, when pressed simultaneously with the
Ctrl key during a session with an attached serial device, will suspend the session with the
device and place you in CLI command mode. If None is specified, the value specified in the
Char parameter of the Server CLI command will be used.
Default = None
When set to DTR, the SCS will toggle the port DTR-out signal off for 0.5 s each time a
connection is made to the port. This toggle is required to awaken the console port of some
devices.
Default = None
Control signal to monitor and the state that indicates the target device has power on. The entire
value must be specified; abbreviations are not allowed. The power status monitoring signal
cannot also be used for flow control. Valid values are:
None—Disables power status monitoring
HICTS—CTS high indicates power on
LOCTS—CTS low indicates power on
HIDCD—DCD high indicates power on
LODCD—DCD low indicates power on
HIDSR—DSR high indicates power on
LODSR—DSR low indicates power on
Default = None
SCS commands 57