Operating With The Operation Panel -1 (Factory Setting State); Example For Rotating In Forward Direction At Operating Frequency 5Hz; Example For Rotating In Forward Direction At Operating Frequency 10Hz; Changing The Frequency With The And Buttons During Operation (Mop Function) - Panasonic AAD03011 Instruction Manual

Elevator door controller
Table of Contents

Advertisement

Operating With the Operation Panel -1 (Factory Setting State)

Forward /reverse run function: Start/stop, rotation direction mode setting (Parameter P08=0)
Frequency setting: Digital setting (Parameter P09=0)

[Example for rotating in forward direction at operating frequency 5Hz]

Power ON
Frequency
setting
Run command

[Example for rotating in forward direction at operating frequency 10Hz]

Changing the
frequency
during
operation
[Stopping operation]
Stop command

[Changing the frequency with the and buttons during operation (MOP function)]

The operating frequency can be changed with the and buttons during operation.
If the (up) button is held down, the operating frequency will increase.
If the (down) button is held down, the operating frequency will decrease.
Note ) Once the operating frequency is determined, press the MODE button and then
press the SET button twice to set the operating frequency.
If this is not carried out, this frequency will not be saved when the power is
turned OFF.
26
The main display lamp will turn ON.
MODE
Press the MODE button.
Press the SET button.
SET
(The main display will flicker.)
Press the (up) or (down) buttons
to display 5Hz on the main display.
(The main display will flicker.)
SET
Press the SET button to set the data.
Press the RUN button.
RUN
As the factory setting is the forward
operation, the motor will start rotating in
the forward direction and operate at 5Hz.
MODE
Press the MODE button.
Press the SET button.
SET
(The main display will flicker.)
Press the (up) or (down) buttons
to display 10Hz on the main display.
(The main display will flicker.)
Press the SET button to set the data.
SET
The display will change to the output
frequency, and will reach 10Hz.
STOP
Press the STOP button. The motor will
start to decelerate and will stop.
Main display
0
0
0
F
r
0
0. 5
0
5. 0
0
0
0
0
5. 0
F
r
0
5. 0
1
0. 0
1
0. 0
0
0
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents