Index Name/Selection
3304
DRIVE RATING
0x0000...0xFFFF
(hex)

34 PANEL DISPLAY

3401
SIGNAL1 PARAM
0, 102...162
3402
SIGNAL1 MIN
x...x
3403
SIGNAL1 MAX
x...x
Actual signals and parameters
Description
Displays the drive current and voltage ratings.
Value in format XXXY:
XXX = Nominal current of the drive in Amperes. An "A" indicates decimal
point. For example if XXX is 8A8, nominal current is 8.8 A.
Y = Nominal voltage of the drive:
2 = 200...240 V
4 = 380...480 V
Selection of actual signals to be displayed on the panel
Selects the first signal to be displayed on the control panel in display mode.
3401
LOC
OUTPUT
Parameter index in group
If value is set to 0, no signal is selected.
If parameter
3401
SIGNAL1 PARAM,
SIGNAL3 PARAM values are all set to 0, n.A. is displayed.
Defines the minimum value for the signal selected by parameter
SIGNAL1 PARAM.
Display
value
3407
3406
Note: Parameter is not effective if parameter
setting is DIRECT.
Setting range depends on parameter
Defines the maximum value for the signal selected by parameter
SIGNAL1 PARAM. See the figure for parameter
Note: Parameter is not effective if parameter
setting is DIRECT.
Setting range depends on parameter
3404
3405
491
.
Hz
FWD
01 OPERATING
DATA. E.g. 102 =
3408
SIGNAL2 PARAM and
3402
3403
3404
OUTPUT1 DSP FORM
3401
setting.
3402
3404
OUTPUT1 DSP FORM
3401
setting.
0102
SPEED.
3415
3401
Source value
3401
SIGNAL1 MIN.
0x0000
103
-
-
-
-