TYPE : Data Saving Module (Multi-V)
MODELS : PVDATN000
P/NO : MFL62179506
www.lg.com

Advertisement

Table of Contents
loading

Summary of Contents for LG PVDATN000

  • Page 1 INSTALLATION/ OWNER’S MANUAL CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : Data Saving Module (Multi-V) MODELS : PVDATN000 www.lg.com P/NO : MFL62179506...
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE. Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product WARNING It can result in serious injury or death when the directions are ignored CAUTION It can result in minor injury or product damage when the directions are ignored WARNING...
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS CAUTION In-use • Do not clean using the powerful detergent like solvent but use soft cloths. It will cause fire or product deformation. • Do not press the screen using powerful pressure or select two buttons. It will cause product breakdown or malfunction. •...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS NAME OF EACH PART COMPONENTS SETTING AND USING METHOD Date & Time setting PC Connection for Date & time Setting Data Saving Module Operation Installation Method LED State Data Converter...
  • Page 5: Name Of Each Part

    NAME OF EACH PART NAME OF EACH PART SD Card Slot Reset Switch Battery Socket Power LED Debugger RX LED Connector TX LED Start Switch Dip Switch Communica- tion Connector Outdoor Main State LEDs PCB Connector Debugger Connector For bootloader program writing and debugging. Start Switch On/Off switch for data save.
  • Page 6: Components

    COMPONENTS COMPONENTS Components Data Saving Module (1EA) Screw (1EA) Data Saving Module Exploded view NOTE SD Card and Battery are not provided by LG. You need to purchase Battery(CR2032) separately.
  • Page 7: Setting And Using Method

    - PI232 and LGMV Cable* PI232 Module LGMV Cable - Data Saving Module and Cable Data Saving Module Data Saving Cable - RS232 cable* - Outdoor Main PCB RS232 cable Outdoor Main PCB NOTE The product has ‘*’ mark is not provided by LG.
  • Page 8: Pc Connection For Date & Time Setting

    SETTING AND USING METHOD PC Connection for Date & time Setting Data Saving Module LGMV Cable PC/Notebook PI232 RS232 Outdoor Main PCB USB to Serial Converter • How to connect - Connect Data Saving Module and Multi-V Outdoor Main PCB with Data Saving Cable - Connect PC and PI232 module with RS232 cable.
  • Page 9 SETTING AND USING METHOD Setting • Hyperterminal - Click Windows “Start” ➔ “Programs” ➔ “Accessories” ➔ “Communication” ➔ “Hyper Terminal” Installation method - Click “New Connection” ➔ Write Name ➔ Select Com port ➔ Click OK Connecting Description Connect to serial port...
  • Page 10 SETTING AND USING METHOD - Configure port setting as(2400 bits/sec, flow control : None) ➔ Click OK COM Properties - Push reset button on Data Saving Module. then Data Saving Module information will be shown on your Hyper Terminal Start Data Saving Module...
  • Page 11 SETTING AND USING METHOD - A Command mode can be available by clicking space bar three times. Then “------START COMMAND------” message will be displayed. Start Command - Type “HELP” in the terminal. Then, Program version and guides for command will be displayed in the terminal.
  • Page 12 SETTING AND USING METHOD • How to set date - Type “DATE” : Display currently configured date Input date - Change date : DATE [yyyy-mm-dd] ex) DATE 2013-07-15 - Check modified date after typing new date. Check and Change date NOTE In case of replacing a battery, Date or Time is not Correct.
  • Page 13 SETTING AND USING METHOD • How to set time - Type “TIME” : Display currently configured time Input time - Change time : TIME [hh:mm:ss] ex) TIME 16:30:25 - Check modified time after typing new time. Check and Change time...
  • Page 14 SETTING AND USING METHOD • How to exit terminall - Type “QUIT” and then click “Enter” key. Then, “-------STOP COMMAND--------” Message will be displayed. Stop command Mode...
  • Page 15: Data Saving Module Operation

    SETTING AND USING METHOD Data Saving Module Operation Requirements - Data Saving module - SD Memory card - Battery (CR2032) • The outline of Data Saving Module SD Card Slot Battery Socket • SD Memory Card. - Use 2GB ~ 8GB SD or SDHC - FAT32 format should be preceded before in use.
  • Page 16 SETTING AND USING METHOD Operation Outdoor Main PCB NOTE • Default state of dip switch is all off. Data Saving Module Step 1. Turn off start switch in Data Saving Module. Step 2. Dip switch position depend on the model. SW1 (ON) &...
  • Page 17: Installation Method

    SETTING AND USING METHOD Installation Method ① Join the front case and the rear case. ② Anchor the front case at holes using anchor screws ③ Join the case in the Multi-V Control Box, anchor the case at holes using anchor screws.
  • Page 18 SETTING AND USING METHOD ④ Connect connection wire to outdoor Main PCB. CAUTION • Install the product on flat surface and screw 4 places. Otherwise the Data Saving Module may not be anchored properly • Do not screw too tightly. It may cause deformation of the case. •...
  • Page 19: Led State

    SETTING AND USING METHOD LED State Power LED On / Off State Yellow RX LED Writing State Green TX LED Error State • Green LED : Display current state - On recording : Blinking in 10 seconds interval - When SD memory card is initially inserted or memory capacity calculation is operated at every minutes : ON for several minutes(seconds) →...
  • Page 20: Data Converter

    SETTING AND USING METHOD Data Converter • Data Converter SD data converter is windows PC based program that converts encoded file to an easy form of readable file for user. • When execute DataConverter(130609).exe file, it displays as belows. - Select file for convert (multiple selection is supported) - Model Type Selection (if selected file is Multi-V IV then model type will be automatically checked) - Output File Selection (depend on the IDU num or HR unit existence)
  • Page 21 PVDATN000 Those products identified by the Product Type and Model Range above from LG Electronics, Inc. ("LGE") contain the open source software de- tailed below. Please refer to the indicated open source licenses (as are included following this notice) for the terms and conditions of their use.
  • Page 22 c) If the modified program normally reads commands interactively when run, you must cause it, when started running for such interactive use in the most ordinary way, to print or display an announcement including an appropriate copyright notice and a notice that there is no warranty (or else, saying that you provide a warranty) and that users may redistribute the program under these conditions, and telling the user how to view a copy of this License.
  • Page 23 Foundation. If the Program does not specify a version number of this License, you may choose any version ever published by the Free Software Foundation. 10. If you wish to incorporate parts of the Program into other free programs whose distribution conditions are different, write to the author to ask for permission.