24.6
17.0
.969
.669
RoHS Directive compatibility information
http://www.nais-e.com/
SPECIFICATIONS
Contact
Arrangement
Contact material
Initial contact resistance (Initial)
(By voltage drop 6 V DC 1A)
Contact voltage drop
Nominal switching
capacity
Rating
Max. carrying current
Min. switching capacity
Mechanical (at 120 cpm)
Resistive load
Expected life
(min. operations)
Electrical
Motor load
Coil
Nominal operating power
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Remarks
*
1
At nominal switching capacity, operating frequency: 1s ON, 9s OFF
*
2
N.O.: at 5 A (steady), 25 A (inrush)/N.C.: at 20 A (brake) 14 V DC, operating
frequency: 0.5s ON, 9.5s OFF
*
At 20A 14 V DC (Motor lock), operating frequency: 0.5s ON, 9.5s OFF
3
*
Measurement at same location as "Initial breakdown voltage" section
4
*
Detection current: 10mA
5
*
Excluding contact bounce time
6
*
Half-wave pulse of sine wave: 11ms; detection: 10 s
7
*
Half-wave pulse of sine wave: 6ms
8
*
Detection time: 10 s
9
TYPICAL APPLICATIONS
• Power windows
• Auto door lock
• Electrically powered sunroof
• Electrically powered mirror, etc.
TWIN POWER SILENT
AUTOMOTIVE RELAY
FEATURES
• Silent
Noise has been reduced by
18.5
approximately 20 dB, using our own
.728
silencing design.
• Twin (1 Form C
Forward/reverse motor control is possible
mm
inch
with a single relay.
• Sealed construction
• Simple footprint enable ease of PC
1 Form C
Ag alloy (Cadmium free)
Typ. 6 m
(N.O.)
Typ. 9 m
(N.C.)
Max. 0.2V (at 10 A)
N.O.: 20 A 14 V DC
N.C.: 10 A 14 V DC
35 A for 2 minutes,
25 A for 1 hour
(12 V, at 20
C68
30 A for 2 minutes,
20 A for 1 hour
(12 V, at 85
C185
1 A 12 V DC
#1
Min. 10
7
Min. 10
5
*
1
Min. 2 10
*
5
Min. 10
5
*
3
640 mW
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
2)
Characteristics
2
Max. operating speed
(at nominal switching capacity)
Initial insulation resistance*
Initial breakdown
voltage*
5
Operate time*
6
(at nominal voltage)(at 20
F)
Release time*
6
(at nominal voltage)(at 20
F)
Shock resistance
Vibration resistance
2
Conditions for
operation, transport
and storage*
11
(Not freezing and
condensing at low
temperature)
Mass
*
10
Time of vibration for each direction;
X, Y, direction: 2 hours
Y
X
Z direction: 4 hours
Z
*
Refer to Conditions for operation, transport and storage mentioned in AMBIENT
11
ENVIRONMENT.
Please inquire if you will be using the relay in a high temperature atmosphere
(110 C
230
F).
ORDERING INFORMATION
Contact arrangement
1 Form C
Standard packing: Carton(tube package) 32pcs. Case: 800pcs.
CR RELAYS
board layout
Common
Coil
Normally
Open
4
Min. 100 M
Between open
500 Vrms for 1 min.
contacts
Between contacts
500 Vrms for 1 min.
and coil
Max. 10 ms (initial)
C68
F)
Max. 10 ms (initial)
C68
F)
Functional*
Min. 100 m/s
7
Destructive*
8
Min. 1,000 m/s
10 Hz to 100 Hz,
Functional*
9
Min. 44.1 m/s
10 Hz to 500 Hz,
Destructive*
10
Min. 44.1 m/s
Ambient
–40 C to +85 C
temperature
–40 F to +185 F
Humidity
5% R.H. to 85% R.H.
Approx.
Ex. CR
2
–
12 V
Coil voltage(DC)
2
CR
Coil
Normally
Closed
6 cpm
(at 500 V DC)
{10G}
2
2
{100G}
2
{4.5G}
{4.5G}
2
12.5g.44 oz
12 V