Adjust the Image Quality
[Image Adjustment] tab
Important
The settings may be different for different camera models. For
details, see the camera manual.
➀ [Exposure]
The settings change according to the selected
exposure setting.
• [Not Specified]
Use the camera's exposure setting.
• [Auto]
Automatically control the exposure.
• [Auto (Flickerless)]
Reduce flicker from light sources, such as
fluorescent lighting. The shutter speed is
automatically adjusted according to the lighting
conditions.
• [Auto (Shutter Priority)]
Specify the shutter speed.
Record on a Regular Basis (Repeating Weekly Schedules)
The following exposure compensation setting is
displayed when [Auto], [Auto (Shutter Priority)] or [Auto
(Flickerless)] is selected.
[Compensation]: Specify exposure compensation
using seven levels, from -3 to +3, or [Not
specified]. Select negative values to darken the
image and positive values to lighten the image.
[Metering Mode]: Specify the metering mode setting:
[Center-weighted], [Average], or [Spot].
Metering mode
Center-weighted
Meters the entire image, focusing on the
center of the image. A correct exposure is
obtained for a subject near the center of the
image, even though the periphery may be
slightly darker or lighter. Use for subjects
that are in the center of the image.
Average
Meters an average of the entire scene.
A uniform exposure is obtained even when
the scene has significant differences in
brightness. Use for scenes where, for
example, cars are passing through or
people are entering and exiting.
Spot
Meters the center of the scene.
The correct exposure is obtained for a
subject near the center of the scene,
irrespective of the brightness of the
periphery. Use if the subject is lit by a
spotlight or is backlit, where the exposure
should be adjusted to the center of the
scene.
[Shutter]: Specify the shutter speed when [Exposure]
is set to [Auto (Shutter Priority)] using 12 levels,
from 1/8 to 1/8000 seconds.