Power and Heat Specifications

The following table lists the electrical power requirements.
Table 3 Power Requirements
Component
Node Pair, no drives, no add-on
host adapters
4-port 8 Gb/s Fibre Channel
Adapter
2-port 10 Gb/s iSCSI/FCoE
Adapter
HP M6710 2.5 inch 2U SAS Drive
Enclosure, no drives
HP M6720 3.5 inch 4U SAS Drive
Enclosure, no drives
100 GB SLC SSD
200 GB SLC SSD
400 GB SLC SSD
480 GB SLC SSD
920 GB SLC SSD
480 GB cMLC SSD
1920 GB cMLC SSD
NOTE:
Refer to

Environmental Specifications

The operating site must comply with the following environmental specifications.
Table 4 Environmental Specifications
Altitude
Temperature
Shipping Temperature
Humidity
Shipping Humidity
Vibration
Shock
For more information, refer to
Idle (watts/BTU/hr)
236 W / 803
24 W / 81.72
34 W / 1 15.77
150 / 512 (average)
164 / 559 (average)
1.4 / 4.8
1.4 / 4.8
2.2 / 3.7
2.2 / 7.49
2.0 / 6.7
3.2 / 1 1
3.5/ 1 1.9
"Power Requirements" (page 22)
10,000ft/ 3,024m Operational
40,000ft/ 12,192m Shipping
Operating: 41–104° F (5–40° C) - Reduce rating by 1° F for each 1000 ft altitude (1.8°
C/1,000 m)
Non–operating: 32–203° F (0–95° C)
32–140° F (0–60° C)
10–90% non-condensing
10–90% non-condensing
Operating: 0.25 G, Sine, 5-500 Hz; 0.15 Grms Random, 5- 1 00 Hz
Non-operating: 0.5G, Sine, 5-500 Hz
Operating: 2 G, 1 1ms, half-sine
Non-operating: 10 G, 1 1ms, half-sine
"Structural/Environmental Considerations" (page 18)
Transactional (watts/BTU/hr)
398 W / 1357
32.6 / 1 1 1
40 W / 136.4
150 / 512 (average)
164 / 559 (average)
3.9 / 13.3
3.9 / 13.3
7.5 / 12.6
5.5 / 18.7
5.2 / 17.8
7.1 / 24.4
8.9 / 30.5
for complete details.