ABB TPU2000 Technical Manual page 293

Modbus/modbus plus/ modbus tcp/ip automation
Table of Contents

Advertisement

33
150P-1D
34
150P-2D
35
150N-1D
36
150G-2D
37
46-1D
38
46-2D
39
PATA
40
PBTA
41
PCTA
42
PUA
43
63
44
THRUFA
45
TFCA
46
TFKA
47
TFSCA
48
DTC
49
OCTC
50
PDA
51
NDA
52
PRIM
53
ALT1
54
ALT2
55
STCA
56
87T*
57
87H*
58
2HROA*
59
5HROA*
60
AHROA*
61
51P-1*
62
51P-2*
63
50P-1*
64
150P-1*
65
50P-2*
66
150P-2*
67
51N-1*
68
51G-2*
69
50N-1*
70
150N-1*
71
50G-2*
72
150G-2*
73
46-1*
74
46-2*
75
63*
76
ULO1
77
ULO2
78
ULO3
79
ULO4
80
ULO5
81
ULO6
82
ULO7
83
ULO8
84
ULO9
85
LOADA
86
OCA-1
87
OCA-2
88
HLDA-1
89
LLDA-1
90
HLDA-2
91
LLDA-2
TPU2000/2000R Modbus/Modbus Plus Automation Guide
2nd Wdg 1 Phase Inst Disabled Alarm
2nd Wdg 2 Phase Inst Disabled Alarm
2nd Wdg 1 Neutral Inst Disabled Alarm
2nd Wdg 2 Ground Inst Disabled Alarm
Wdg 1 Neg Sequence Time OC Disabled Alarm
Wdg 2 Neg Sequence Time OC Disabled Alarm
Phase A LED Alarm
Phase B LED Alarm
Phase C LED Alarm
Pickup Alarm
Sudden Pressure Input Alarm
Through Fault Alarm
Through Fault Counter Alarm
Through Fault KAmp Summation Alarm
Through Fault Cycle Summation Alarm
Differential Trip Counter Alarm
Overcurrent Trip Counter Alarm
Phase Current Demand Alarm
Neutral Current Demand Alarm
Primary Set Enabled Alarm
Alt1 Set Enabled Alarm
Alt2 Set Enabled Alarm
Settings Table Changed Alarm
Percentage Diff Sealed In Alarm
High Set Inst Diff Sealed In Alarm
2nd Harmonic Restraint Sealed In Alarm
5th Harmonic Restraint Sealed In Alarm
All Harmonic Restraint Sealed In Alarm
Wdg 1 Phase Time OC Sealed In Alarm
Wdg 2 Phase Time OC Sealed In Alarm
1st Wdg1 Phase Inst OC Sealed In Alarm
2nd Wdg1 Phase Inst OC Sealed In Alarm
1st Wdg2 Phase Inst OC Sealed In Alarm
2nd Wdg2 Phase Inst OC Sealed In Alarm
Wdg1 Neutral Time OC Sealed In Alarm
Wdg2 Ground Time OC Sealed In Alarm
1st Wdg1 Neutral Inst OC Sealed In Alarm
2nd Wdg1 Neutral Inst OC Sealed In Alarm
1st Wdg2 Ground Inst OC Sealed In Alarm
2nd Wdg2 Ground Inst OC Sealed In Alarm
Wdg1 Neg Sequence Time OC Sealed In Alarm
Wdg2 Neg Sequence Time OC Sealed In Alarm
Sudden Pressure Input Sealed In Alarm
User Logical Output 1
User Logical Output 2
User Logical Output 3
User Logical Output 4
User Logical Output 5
User Logical Output 6
User Logical Output 7
User Logical Output 8
User Logical Output 9
Load Current
Overcurrent Alarm, Winding 1
Overcurrent Alarm, Winding 2
High Level Detection Alarm, Winding 1
Low Level Detection Alarm, Winding 1
High Level Detection Alarm, Winding 2
Low Level Detection Alarm, Winding 2
283

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tpu2000r

Table of Contents