Lenovo Flex System x220 Installation And Service Manual

Lenovo Flex System x220 Installation And Service Manual

Compute node
Hide thumbs Also See for Flex System x220:
Table of Contents

Advertisement

Quick Links

Flex System x220 Compute Node
Installation and Service Guide
Machine Types: 7906, 2585

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo Flex System x220

  • Page 1 Flex System x220 Compute Node Installation and Service Guide Machine Types: 7906, 2585...
  • Page 2 Environmental Notices and User Guide documents on the IBMDocumentation CD. Tenth Edition (August 2016) © Copyright Lenovo 2014, 2016. LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant to a General Services Administration “GSA” contract, use, reproduction, or disclosure is subject to restrictions set forth in Contract...
  • Page 3: Table Of Contents

    Brocade documentation ... . Viewing the network access tag ..The Lenovo Documentation CD ..Logging in to the IMM2 Web interface..
  • Page 4 Index....replaceable units (CRUs)... Removing the adapter-retention assembly . . Flex System x220 Compute Node Installation and Service Guide...
  • Page 5: Safety

    Avant d'installer ce produit, lisez les consignes de sécurité. Vor der Installation dieses Produkts die Sicherheitshinweise lesen. Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza. Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. © Copyright Lenovo 2014, 2016...
  • Page 6: Safety Statements

    Be sure to read all caution and danger statements in this documentation before you perform the procedures. Read any additional safety information that comes with your system or optional device before you install the device. Flex System x220 Compute Node Installation and Service Guide...
  • Page 7 Do not: • Throw or immerse into water • Heat to more than 100°C (212°F) • Repair or disassemble Dispose of the battery as required by local ordinances or regulations. © Copyright Lenovo 2014, 2016...
  • Page 8 Hazardous energy is present when the blade is connected to the power source. Always replace the blade cover before installing the blade. UL regulatory information This device is for use only with Listed chassis. Flex System x220 Compute Node Installation and Service Guide...
  • Page 9: Chapter 1. Introduction

    Chapter 1. Introduction The Lenovo Flex System x220 Compute Node Types 2585 and 7906 is a high-availability, scalable compute node that is optimized to support the next-generation microprocessor technology and is ideally suited for medium and large businesses. The Flex System x220 Compute Node is supported in the Flex System Enterprise Chassis only.
  • Page 10: Related Documentation

    Safety Information document. • Lenovo Warranty Information This printed document contains the warranty terms and a pointer to the Lenovo Statement of Limited Warranty. • Environmental Notices and User Guide This document is in PDF.
  • Page 11: The Lenovo Documentation Cd

    You can run the Documentation CD on any computer that meets the hardware and software requirements. Hardware and software requirements Use this information to determine the minimum hardware and software requirements. The Lenovo Documentation CD requires the following minimum hardware and software: • MicrosoftWindows • 100 MHz microprocessor •...
  • Page 12: Notices And Statements In This Document

    • Danger: These statements indicate situations that can be potentially lethal or hazardous to you. A danger statement is placed just before the description of a potentially lethal or hazardous procedure step or situation. Flex System x220 Compute Node Installation and Service Guide...
  • Page 13: Features And Specifications

    USB media drives and devices. The Flex System chassis uses USB for internal communication with these devices. The following table is a summary of the features and specifications of the Flex System x220 Compute Node. Table 1. Features and specifications...
  • Page 14: What Your Compute Node Offers

    The ServerGuide Setup and Installation CD, which you can download from the web, provides programs to help you set up the compute node and install a Windows operating system. The ServerGuide program Flex System x220 Compute Node Installation and Service Guide...
  • Page 15 For more information, see “Using the ServerGuide Setup and Installation CD” on page 44. • Lenovo X-Architecture Lenovo X-Architecture systems combine proven, innovative designs to make your x86-processor-based compute node powerful, scalable, and reliable. For more information, see http://shop.lenovo.com/us/en/systems/ servers/mission-critical/.
  • Page 16 IMM management settings. The IMM2 communicates with the Lenovo Flex System Chassis Management Module (CMM) and Flex System Manager management software (if installed). – The CMM is a hot-swap module that provides systems-management functions for all components in an Flex System chassis.
  • Page 17: Lenovo Xclarity Administrator

    Fsetup.html. – Free 90-day trial Lenovo XClarity Administrator offers a free, 90-day trial license that enables you to use all available features (including operating-system deployment, firmware maintenance, and configuration management) for a limited time. After 90 days, you can continue to use Lenovo XClarity Administrator to manage and monitor your hardware for free;...
  • Page 18 Lenovo XClarity Administrator provides a centralized view of all events and alerts that are generated from the managed endpoints. When a CMM or IMM detects an issue, an alert or event is passed to the Lenovo XClarity Administrator and is displayed in the events or alerts log. A summary of all alerts and events is visible from the Dashboard and the Status bar.
  • Page 19: Reliability, Availability, And Serviceability Features

    Reliability, availability, and serviceability features Three of the most important features in compute node design are reliability, availability, and serviceability (RAS). These RAS features help to ensure the integrity of the data that is stored in the compute node, the availability of the compute node when you need it, and the ease with which you can diagnose and correct problems.
  • Page 20: Power, Controls, And Indicators

    Power button/LED Check log KVM connector Identify LED Hard disk drive activity LED (green) When this green LED is lit, it indicates that there is activity on the hard disk drive. Flex System x220 Compute Node Installation and Service Guide...
  • Page 21 • From the CMM web interface, select Compute Nodes from the Chassis Management menu. For more information, see the the "Flex System Chassis Management Module: User's Guide" at http://pic.dhe.ibm.com/infocenter/flexsys/information/topic/com.lenovo.acc.cmm.doc/ cmm_user_ guide.html. All fields and options are described in the CMM web interface online help.
  • Page 22 If an operating system is running, you might have to press the button for approximately 4 seconds to initiate the shutdown. Attention: Pressing the button for 4 seconds forces the operating system to shut down immediately. Data loss is possible. Flex System x220 Compute Node Installation and Service Guide...
  • Page 23: Console Breakout Cable

    CMM power command and the CMM web interface. – For more information about the CMM power command, see the "Flex System Chassis Management Module: Command-Line Interface Reference Guide" at http://pic.dhe.ibm.com/infocenter/flexsys/information/topic/com.lenovo.acc.cmm.doc/cli_ command_ power.html. – From the CMM web interface, select Compute Nodes from the Chassis Management menu.
  • Page 24: Turning Off The Compute Node

    • You can press the power button on the compute node (see “Compute node controls, connectors, and LEDs” on page 12). This starts an orderly shutdown of the operating system, if this feature is supported by the operating system. Flex System x220 Compute Node Installation and Service Guide...
  • Page 25: System-Board Layouts

    System Manager management software (if installed). – For more information about the CMM power command, see the "Flex System Chassis Management Module: Command-Line Interface Reference Guide" at http://pic.dhe.ibm.com/infocenter/flexsys/information/topic/com.lenovo.acc.cmm.doc/cli_ command_ power.html. – From the CMM web interface, select Compute Nodes from the Chassis Management menu.
  • Page 26: System-Board Leds

    Microprocessor 2 error error 1 - 6 error System-board switches Use this information to locate the system-board switches. The following illustration shows the location of the switch block on the system board. Flex System x220 Compute Node Installation and Service Guide...
  • Page 27 The following table describes the functions of the switches on switch block SW8, the NMI button, and the power button. Table 3. System-board switches Switch Description Switch setting Definition SW8-1 Password override The default position is Off. Changing this switch to the On position overrides the power-on password.
  • Page 28 Pressing this recessed button causes the compute node to stop doing what it is doing. Power button The default position is Off. Pressing this button turns on or turns off the compute node. Flex System x220 Compute Node Installation and Service Guide...
  • Page 29: Chapter 2. Configuring

    • Lenovo ToolsCenter Bootable Media Creator You can use Lenovo ToolsCenter Bootable Media Creator to create bootable media that is suitable for applying firmware updates and running preboot diagnostics. Using Lenovo ToolsCenter Bootable Media Creator, you can create a single bootable image on supported media (such as CD, DVD, ISO image, USB flash drive, or set of PXE files) that bundles multiple Flex System tools and updates from UpdateXpress System Packs, which contain Windows and Linux®...
  • Page 30: Recovering A Uefi Image

    The backup page version might not be the same as the primary page version. You can then recover or restore the original primary page UEFI. Note: Changes are made periodically to the Lenovo website. The actual procedure might vary slightly from what is described in this document.
  • Page 31: Configuring The Compute Node

    You can install up to two hard disk drives in the compute node and implement RAID level-0 (striping) or RAID level-1 (mirroring) arrays in operating systems that are listed on the ServerProven list at http://www.lenovo.com/ serverproven/. For more about configuring the ServeRAID controller, see “Configuring a RAID array” on page 33.
  • Page 32: Using The Setup Utility

    Select this choice to view configuration information, including the ID, speed, and cache size of the microprocessors, machine type and model of the compute node, the serial number, the system Universally Unique Identifier (UUID), and the amount of installed memory. – Product Data Flex System x220 Compute Node Installation and Service Guide...
  • Page 33 Select this choice to view the system-board identifier, the revision level or issue date of the firmware, the integrated management module II and diagnostics code, and the version and date. This choice is on the full UEFI Setup utility menu only. •...
  • Page 34 Select this choice to restore the IMM2 to the manufacturing default settings. The IMM2 controller restarts after you restore the settings. – Reset IMM Select this choice to restart the IMM2 controller. Flex System x220 Compute Node Installation and Service Guide...
  • Page 35 – Recovery Select this choice to view or change the system recovery parameters. – POST Attempts Select this choice to define the number of times to attempt POST before invoking the recovery procedures. – System Recovery Select this choice to configure the recovery settings. •...
  • Page 36: Nx Boot Failure

    Configuration changes, such as added devices or adapter firmware updates, and firmware or application code problems can cause the compute node to fail the power-on self-test (POST). If the compute node fails to POST, it responds in either of the following ways: Flex System x220 Compute Node Installation and Service Guide...
  • Page 37: Setting The Boot Protocol To Boot From Legacy Devices Using The Setup Utility

    • The compute node restarts automatically and attempts POST again. • The compute node hangs and you must manually restart the compute node for the compute node to attempt POST again. After a specified number of consecutive attempts (automatic or manual), the Nx boot failure feature causes the compute node to revert to the default UEFI configuration and start the Setup utility, so that you can make the necessary corrections to the configuration and restart the compute node.
  • Page 38: Using The Boot Selection Menu Program

    You can use the ASU under any supported operating system, or you can use the Bootable Media Creator or a Windows- or Linux-based toolkit to create bootable media that contains the ASU. For information about the ASU and instructions for downloading and unpacking the ASU code, see https://support.lenovo.com/us/en/ documents/LNVO-ASU and the Advanced Settings Utility User's Guide.
  • Page 39 xxxx is the 4-digit machine type of the compute node. is the 3-digit model number of the compute node. Step 2. Enter the following command: asu set SYSTEM_PROD_DATA.SysInfoSerialNum zzzzzzz –kcs where zzzzzzz is the 7-character serial number of the compute node. Step 3.
  • Page 40: Remotely Over A Lan

    SYSTEM_PROD_DATA.SysInfoSerialNum zzzzzzz –host ipaddress [–user userid][–password password] where zzzzzzz is the 7-character serial number of the compute node. Step 3. Enter the following command: asu set SYSTEM_PROD_DATA.SysEncloseAssetTagaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa –host [–user userid][–password password] ipaddress Flex System x220 Compute Node Installation and Service Guide...
  • Page 41: Configuring A Raid Array

    Creating an array using the integrated ServeRAID C105 controller Use these instructions to configure a software RAID array on the Flex System x220 Compute Node using the integrated ServeRAID C105 controller. Important: You must create the software RAID array before you install the operating system on the compute node.
  • Page 42 • RAID0 is the only option available if there is just one hard disk drive installed. • RAID0 and RAID1 are available if two hard disk drives are installed. Step 6. On the Create Configuration screen, select Select Drives. The Select Drives screen is displayed. Flex System x220 Compute Node Installation and Service Guide...
  • Page 43 5. ServeRAID C105 is automatically disabled when ServeRAID H1135 is installed. Creating an array using the optional ServeRAID H1135 controller Use these instructions to configure a RAID array on the Flex System x220 Compute Node using an optional ServeRAID H1135 controller.
  • Page 44 The following illustration shows the System Settings window. Step 4. From the Storage window, use the arrow keys to select the controller you want to configure; then, press Enter. The following illustration shows the Storage window. Flex System x220 Compute Node Installation and Service Guide...
  • Page 45 Step 5. After you select the controller that you want to configure, the Controller Configuration window is displayed. The following illustration is an example of the Controller Configuration window. Step 6. Press Enter to continue. The Configuration Options window is displayed. The following illustration shows the Configuration Options window with Controller Management selected.
  • Page 46 Select an option: Select Controller Management to view and manage controller properties, create volumes, import or delete foreign volumes and save or clear controller events. The following illustration shows the Controller Management window. Flex System x220 Compute Node Installation and Service Guide...
  • Page 47 Select Physical Disk Management to manage all disks. The following illustration shows the Physical Disk Management window. For additional information about this application, see http://public.dhe.ibm.com/systems/support/ system_x_pdf/ ibm_doc_mpt2sas_hiic-2011-09_user-guide.pdf. See the following documents for more detailed information about using the ServeRAID configuration utilities: •...
  • Page 48: Features On Demand

    Setting up the LAN-on-motherboard feature This topic provides information about setting up the LAN-on-motherboard (LOM) feature. Some models of the Flex System x220 Compute Node have an Ethernet LAN-on-motherboard (LOM) controller integrated on the system board. The LOM provides the following features: •...
  • Page 49 No host operating-system changes are required for you to use the LOM features. Network interface cards and host bus adapter functionality (including device management, utilities, and other functions) are transparent to the host operating system. Chapter 2 Configuring...
  • Page 50 Flex System x220 Compute Node Installation and Service Guide...
  • Page 51: Chapter 3. Installing The Operating System

    Use IBM ToolsCenter Bootable Media Creator to create an IBMServerGuide Setup and Installation CD for deploying Windows operating systems and updates from UpdateXpress System Packs. For more information about the IBM Bootable Media Creator, see https://support.lenovo.com/ us/en/documents/LNVO-BOMC. To provision a compute node with an operating system by using IBM ToolsCenter Bootable Media Creator, complete the following steps: 1.
  • Page 52: Using The Serverguide Setup And Installation Cd

    • Diskette-free setup, and configuration programs that are based on detected hardware • Device drivers that are provided for the compute node model and detected hardware • Operating-system partition size and file-system type that are selectable during setup Flex System x220 Compute Node Installation and Service Guide...
  • Page 53: Typical Operating-System Installation

    Flex System compute node in a repeatable, predictable manner. When the ServerGuide Scripting Toolkit is used with Lenovo ServerGuide, it provides a total solution for deploying Flex System compute nodes in an unattended mode.
  • Page 54 Flex System x220 Compute Node Installation and Service Guide...
  • Page 55: Chapter 4. Accessing The Imm2

    To access the web interface, you need the IP address of the IMM2. You can locate the IP address by viewing the network access tag. The network access tag is attached to the front of the compute node. The front © Copyright Lenovo 2014, 2016...
  • Page 56: Logging In To The Imm2 Web Interface

    • If you are logging in to the IMM2 for the first time after installation, the IMM2 defaults to a Dynamic Host Configuration Protocol (DHCP). If a DHCP host is not available, the IMM2 assigns a static IP address of Flex System x220 Compute Node Installation and Service Guide...
  • Page 57: Imm2 Action Descriptions

    • You must set the CMM to use the Secure security policy for the IMM2 to power on the compute node and for the IMM2 to function properly. See “Secure security policy” in the Lenovo Flex System Chassis Management Module Installation Guide.
  • Page 58 Server Timeouts The Server Timeouts page allows you to manage compute node start timeouts to detect and recover from compute node hang occurrences. Flex System x220 Compute Node Installation and Service Guide...
  • Page 59 Table 4. IMM2 actions (continued) Selection Description PXE Network Boot The PXE Network Boot page allows you to change the host compute node startup (boot) sequence for the next restart to attempt a Preboot Execution Environment (PXE)/Dynamic Host Configuration Protocol (DHCP) network startup.
  • Page 60: Accessing The Imm2 Using The Lan Over Usb Interface

    Resolving conflicts with the IMM2 LAN over USB interface Use any of the following actions to resolve LAN over USB conflicts with network configurations and applications. Flex System x220 Compute Node Installation and Service Guide...
  • Page 61: Configuring The Lan Over Usb Interface Manually

    When you install a Windows operating system, there will be an unknown RNDIS device in the Device Manager. Lenovo provides a Windows INF file that identifies this device. The signed version of the INF file is included in all of the Windows versions of the IMM2, UEFI, and DSA update packages. Complete the following steps to install ibm_rndis_server_os.inf.
  • Page 62 Finish. A new local area connection appears. If the message This connection has limited or no connectivity is displayed, ignore this message. Step 10. Return to the Device Manager. IBM USB Remote NDIS Network Device or Lenovo USB Remote NDIS Network Device appears under Network Adapters.
  • Page 63: Chapter 5. Parts Listing, Types 2585 And 7906

    Tier 1 CRU at your request without a service contract, you will be charged for the installation. • Tier 2 customer replaceable unit: You may install a Tier 2 CRU yourself or request Lenovo to install it, at no additional charge, under the type of warranty service that is designated for your compute node.
  • Page 64 GB, 10K 6 Gbps (optional) 81Y9651 Hard disk drive, 2.5 inch hot-swap SAS, 900 GB, 10K 6 Gbps (optional) Hard disk drive, 2.5 inch hot-swap SAS, 146 00FN457 GB, 15K 6 Gbps (optional) Flex System x220 Compute Node Installation and Service Guide...
  • Page 65 Table 6. Parts listing, Types 2585 and 7906 (continued) CRU part number Index Description (Tier 1) CRU part number (Tier 2) Hard disk drive, 2.5 inch hot-swap SAS, 300 00FN460 GB, 15K 6 Gbps (optional) Hard disk drive, 2.5 inch hot-swap SATA, 250 81Y9723 GB 7200 (optional) Hard disk drive, 2.5 inch hot-swap SATA, 500...
  • Page 66 46C9943 (optional) 2 GB memory flash 42D0545 Consumable and structural parts Consumable and structural parts are not covered by the Lenovo Statement of Limited Warranty. Table 7. Consumable and structural parts, Types 2585 and 7906 Index Description Part number Cover (all models)
  • Page 67 If you need help with your order, call the toll-free number that is listed on the retail parts page, or contact your local Lenovo representative for assistance. Chapter 5 Parts listing, Types 2585 and 7906...
  • Page 68 Flex System x220 Compute Node Installation and Service Guide...
  • Page 69: Chapter 6. Troubleshooting

    Chapter 6. Troubleshooting Use this information to diagnose and correct problems that might occur in your Flex System x220 Compute Node. The information in this section describes tools and procedures for solving hardware and software problems. If you cannot diagnose and correct a problem by using the information, see Appendix A “Getting help and technical assistance”...
  • Page 70 LEDs. The following illustration shows the LEDs on the light path diagnostics panel. The following illustration shows the locations of the light path diagnostics LEDs on the system board. Flex System x220 Compute Node Installation and Service Guide...
  • Page 71: Imm Event Log

    DIMM backplane Microprocessor 1 error 7 - 12 error error Battery error Daughter card error Microprocessor 2 DIMM error error error 1 - 6 Light path diagnostics LEDs Use this information to diagnose possible errors that are indicated by the light path diagnostics LEDs. The following table describes the LEDs on the light path diagnostics panel and the light path diagnostics LEDs on the system board.
  • Page 72 Linux operating system come with a current version of IPMItool. For information about IPMItool, complete the following steps. Note: Changes are made periodically to the Lenovo website. The actual procedure might vary slightly from what is described in this document.
  • Page 73: Lenovo Dynamic System Analysis

    2. Click Linux. 3. Click the Linux blueprints tab. 4. Click Blueprints for Linux on IBM systems or Blueprints for Linux on Lenovo systems, and then click Using Intelligent Platform Management Interface (IPMI) on IBM Linux platforms or Using Intelligent Platform Management Interface (IPMI) on Lenovo Linux platforms.
  • Page 74: Dsa Editions

    3. Turn on the compute node (see “Turning on the compute node” on page 15). 4. When the prompt <F2> Diagnostics is displayed, press F2. Flex System x220 Compute Node Installation and Service Guide...
  • Page 75: Dsa Diagnostic Test Results

    For additional information, see the Dynamic System Analysis Installation and User's Guide, which is available at https://support.lenovo.com/us/ en/documents/LNVO-DSA. Help for DSA is available. For help about the DSA CLI, enter help in the command line. For help about the DSA user interface, press F1.
  • Page 76 6. If the system has stopped responding, turn off and restart the system and then run the test again. 7. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action. Flex System x220 Compute Node Installation and Service Guide...
  • Page 77 Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 089-802-000 : CPU Stress Test Aborted CPU Stress Test Aborted. System resource unavailability error. Recoverable Severity Warning Serviceable Automatically notify support User Response Complete the following steps: 1.
  • Page 78 6. If the system has stopped responding, turn off and restart the system and then run the test again. 7. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action. Flex System x220 Compute Node Installation and Service Guide...
  • Page 79 Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM DSA memory stress test results The following messages can result when you run the memory stress test. Test results for the DSA memory stress test The following messages can result when you run the DSA memory stress test.
  • Page 80 202-803-000 : MemStr Test Aborted User pressed Ctrl-C. Recoverable Severity Warning Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM Flex System x220 Compute Node Installation and Service Guide...
  • Page 81 • 202-901-000 : MemStr Test Failed Test Failed. Recoverable Severity Error Serviceable Automatically notify support User Response Complete the following steps: 1. Execute the standard DSA memory diagnostics to validate all memory. 2. Make sure that the DSA Diagnostic code is at the latest level. 3.
  • Page 82 – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 201-000-001 : Standalone Memory Test Passed Quick/Full Memory Test CPU 1 Passed. Recoverable Severity Event Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 83 Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 201-000-002 : Standalone Memory Test Passed Quick/Full Memory Test CPU 2 Passed. Recoverable Severity Event Serviceable Automatically notify support Related links –...
  • Page 84 Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 201-811-001 : Standalone Memory Test Aborted Unable to Locate SMBIOS key "_SM_". Recoverable Severity Warning Flex System x220 Compute Node Installation and Service Guide...
  • Page 85 Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
  • Page 86 Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM Flex System x220 Compute Node Installation and Service Guide...
  • Page 87 • 201-812-001 : Standalone Memory Test Aborted Memory test is not supported for this system. Recoverable Severity Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
  • Page 88 User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. Flex System x220 Compute Node Installation and Service Guide...
  • Page 89 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA –...
  • Page 90 IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 201-814-000 : Standalone Memory Test Aborted Chipset Error: Can not disable Scubbing feature for CPU. Recoverable Severity Warning Flex System x220 Compute Node Installation and Service Guide...
  • Page 91 Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
  • Page 92 Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM Flex System x220 Compute Node Installation and Service Guide...
  • Page 93 • 201-815-000 : Standalone Memory Test Aborted Program Error with Quick Memory Menu Option Selection. Recoverable Severity Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
  • Page 94 User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. Flex System x220 Compute Node Installation and Service Guide...
  • Page 95 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA –...
  • Page 96 IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 201-816-003 : Standalone Memory Test Aborted Program Error with Full Memory Menu Option Selection. Recoverable Severity Warning Flex System x220 Compute Node Installation and Service Guide...
  • Page 97 Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
  • Page 98 Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM Flex System x220 Compute Node Installation and Service Guide...
  • Page 99 • 201-818-003 : Standalone Memory Test Aborted Unable to Locate SMBIOS key "_SM_". Recoverable Severity Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
  • Page 100 User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. Flex System x220 Compute Node Installation and Service Guide...
  • Page 101 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA –...
  • Page 102 IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 201-820-002 : Standalone Memory Test Aborted Memory Upper limit is less than 16 Mbytes. Recoverable Severity Warning Flex System x220 Compute Node Installation and Service Guide...
  • Page 103 Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
  • Page 104 Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM Flex System x220 Compute Node Installation and Service Guide...
  • Page 105 • 201-821-002 : Standalone Memory Test Aborted Variable range MTRR registers are larger than fixed range MTRR registers. Recoverable Severity Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
  • Page 106 User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. Flex System x220 Compute Node Installation and Service Guide...
  • Page 107 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA –...
  • Page 108 Latest level of BMC/IMM • 201-824-001 : Standalone Memory Test Aborted Node Interleave feature must be OFF. Go to Setup and disable Node Interleave option and then re-run the test. Recoverable Severity Flex System x220 Compute Node Installation and Service Guide...
  • Page 109 Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
  • Page 110 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website Flex System x220 Compute Node Installation and Service Guide...
  • Page 111 – Latest level of DSA – Latest level of BMC/IMM • 201-826-001 : Standalone Memory Test Aborted BIOS: Memory Controller has been disabled. Go to Setup and Enable Memory Controller. Recoverable Severity Warning Serviceable Automatically notify support User Response Complete the following steps: 1.
  • Page 112 201-827-000 : Standalone Memory Test Aborted BIOS: ECC function has been disabled by BIOS. Go to Setup and enable ECC generation. Recoverable Severity Warning Serviceable Automatically notify support User Response Complete the following steps: Flex System x220 Compute Node Installation and Service Guide...
  • Page 113 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
  • Page 114 IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 201-844-000 : Standalone Memory Test Aborted Chipset Error: Problem in masking MSR machine check control MASK registers. Recoverable Flex System x220 Compute Node Installation and Service Guide...
  • Page 115 Severity Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
  • Page 116 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA Flex System x220 Compute Node Installation and Service Guide...
  • Page 117 – Latest level of BMC/IMM • 201-845-000 : Standalone Memory Test Aborted Chipset Error: Problem clearing MSR machine check control registers. Recoverable Severity Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
  • Page 118 User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. Flex System x220 Compute Node Installation and Service Guide...
  • Page 119 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA –...
  • Page 120 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 201-859-003 : Standalone Memory Test Aborted INVALID XSECSRAT type. Recoverable Severity Warning Flex System x220 Compute Node Installation and Service Guide...
  • Page 121 Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
  • Page 122 Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM Flex System x220 Compute Node Installation and Service Guide...
  • Page 123 • 201-860-003 : Standalone Memory Test Aborted No OEM0 type 1 found. Recoverable Severity Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
  • Page 124 User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. Flex System x220 Compute Node Installation and Service Guide...
  • Page 125 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA –...
  • Page 126 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 201-862-002 : Standalone Memory Test Aborted No OEM1 structure found. Recoverable Severity Warning Flex System x220 Compute Node Installation and Service Guide...
  • Page 127 Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
  • Page 128 Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM Flex System x220 Compute Node Installation and Service Guide...
  • Page 129 • 201-863-002 : Standalone Memory Test Aborted No IBMERROR key in OEM1 structure. Recoverable Severity Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
  • Page 130 User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. Flex System x220 Compute Node Installation and Service Guide...
  • Page 131 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA –...
  • Page 132 Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 201-865-001 : Standalone Memory Test Aborted No XSECSRAT key in OEM0 structure. Recoverable Severity Warning Flex System x220 Compute Node Installation and Service Guide...
  • Page 133 Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
  • Page 134 Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM Flex System x220 Compute Node Installation and Service Guide...
  • Page 135 • 201-866-001 : Standalone Memory Test Aborted EFI-SAL Invalid parameter from GetMemoryMap function. Recoverable Severity Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
  • Page 136 User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. Flex System x220 Compute Node Installation and Service Guide...
  • Page 137 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA –...
  • Page 138 – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 201-868-000 : Standalone Memory Test Aborted EFI/SAL: Buffer allocated in GetMemoryMap too small. Recoverable Severity Warning Flex System x220 Compute Node Installation and Service Guide...
  • Page 139 Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
  • Page 140 Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM Flex System x220 Compute Node Installation and Service Guide...
  • Page 141 • 201-869-000 : Standalone Memory Test Aborted EFI/SAL Invalid parameter from GetMemoryMap function. Recoverable Severity Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
  • Page 142 User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. Flex System x220 Compute Node Installation and Service Guide...
  • Page 143 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA –...
  • Page 144 Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 201-870-003 : Standalone Memory Test Aborted CPU Doamin in ACPI not valid. Recoverable Severity Warning Flex System x220 Compute Node Installation and Service Guide...
  • Page 145 Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
  • Page 146 Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM Flex System x220 Compute Node Installation and Service Guide...
  • Page 147 • 201-871-003 : Standalone Memory Test Aborted Data Mis-compare encountered. Recoverable Severity Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3.
  • Page 148 User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. Flex System x220 Compute Node Installation and Service Guide...
  • Page 149 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA –...
  • Page 150 Latest level of DSA – Latest level of BMC/IMM • 201-878-002 : Standalone Memory Test Aborted Sparing feature must be turned OFF. Go to setup and turn the sparing feature OFF. Recoverable Severity Warning Flex System x220 Compute Node Installation and Service Guide...
  • Page 151 Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
  • Page 152 Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM Flex System x220 Compute Node Installation and Service Guide...
  • Page 153 • 201-885-002 : Standalone Memory Test Aborted Processor does not support MTRR register manipulation. Can not write to memory without cache. Recoverable Severity Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
  • Page 154 User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. Flex System x220 Compute Node Installation and Service Guide...
  • Page 155 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related links – IBM Support website – Latest level of DSA –...
  • Page 156 • 201-899-001 : Standalone Memory Test Aborted Memory Diagnostics Test Aborted by user. Recoverable Severity Warning Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA Flex System x220 Compute Node Installation and Service Guide...
  • Page 157 – Latest level of BMC/IMM • 201-899-002 : Standalone Memory Test Aborted Memory Diagnostics Test Aborted by user. Recoverable Severity Warning Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM •...
  • Page 158 6. Make sure that all DIMMs are enabled in the Configuration/Setup Utility program. 7. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action. Related links – IBM Support website Flex System x220 Compute Node Installation and Service Guide...
  • Page 159 – Latest level of DSA – Latest level of BMC/IMM • 201-901-002 : Standalone Memory Test Failed Memory Diagnostics Test Failed. Recoverable Severity Error Serviceable Automatically notify support User Response Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
  • Page 160 IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 215-801-000 : Optical Drive Test Aborted Optical Drive Test Aborted. Unable to communicate with driver. Recoverable Severity Flex System x220 Compute Node Installation and Service Guide...
  • Page 161 Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Make sure that the DSA Diagnostic code is at the latest level. 2. Run the test again. 3. Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable if damage is present.
  • Page 162 Rerun the test. 3. Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable if damage is present. 4. Run the test again. Flex System x220 Compute Node Installation and Service Guide...
  • Page 163 5. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 215-901-000 : Optical Drive Test Aborted Optical Drive Test Aborted.
  • Page 164 6. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM Flex System x220 Compute Node Installation and Service Guide...
  • Page 165 DSA tape drive test results The following messages can result when you run the tape drive test. Test results for the DSA tape drive test The following messages can result when you run the DSA tape drive test. • 264-000-000 : Tape Test Passed Tape Test Passed.
  • Page 166 Tape Test Failed. Media is not detected. Recoverable Severity Error Serviceable Automatically notify support User Response Complete the following steps: 1. Clean the tape drive using the appropriate cleaning media and install new media. Flex System x220 Compute Node Installation and Service Guide...
  • Page 167 2. Run the test again. 3. Make sure that the drive firmware is at the latest level. 4. Rerun the test after upgrading to the latest firmware level. 5. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide"...
  • Page 168 5. Make sure that the DSA Diagnostic code is at the latest level. 6. Run the test again. 7. Check the system firmware level and upgrade if necessary. 8. Run the test again. Flex System x220 Compute Node Installation and Service Guide...
  • Page 169 9. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 264-907-000 : Tape Test Failed An error was found in the block address somewhere.
  • Page 170 Warning Serviceable Automatically notify support User Response Complete the following steps: 1. Check cable connections. 2. Rerun the test. 3. Verify that Hard drive supports self test and self test logging. Flex System x220 Compute Node Installation and Service Guide...
  • Page 171 4. If the problem remains, contact your technical-support representative. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 217-900-000 : HDD Test Failed HDD Test Failed. The hard drive self-test detected a failure. Recoverable Severity Error...
  • Page 172 Recoverable Severity Error Serviceable Automatically notify support User Response Complete the following steps: 1. Check cable connections. 2. Rerun the test. 3. Verify whether the firmware is at the latest level. Flex System x220 Compute Node Installation and Service Guide...
  • Page 173 4. Rerun the test. 5. If the problem remains, contact your IBM technical-support representative. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM DSA Nvidia GPU test results The following messages can result when you run the Nvidia GPU test. Test results for the DSA Nvidia GPU test The following messages can result when you run the DSA Nvidia GPU test.
  • Page 174 Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 409-006-000 : Nvidia::DiagnosticServiceProvider::Binomial Test Passed Nvidia GPU Binomial test passed. Recoverable Severity Event Flex System x220 Compute Node Installation and Service Guide...
  • Page 175 Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 409-800-000 : NVIDIA User Diagnostic Test Aborted NVIDIA User Diagnostic test was canceled. Recoverable Severity Event Serviceable Automatically notify support Related links –...
  • Page 176 – Latest level of DSA – Latest level of BMC/IMM • 409-806-000 : Nvidia::DiagnosticServiceProvider::Binomial Test Aborted Nvidia GPU Binomial test was canceled. Recoverable Severity Warning Serviceable Automatically notify support Related links Flex System x220 Compute Node Installation and Service Guide...
  • Page 177 – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 409-900-000 : NVIDIA User Diagnostic Test Failed NVIDIA User Diagnostic Test Failed. Recoverable Severity Event Serviceable Automatically notify support User Response Complete the following steps: 1.
  • Page 178 5. If the problem remains, contact your IBM technical-support representative. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 409-905-000 : Nvidia::DiagnosticServiceProvider::Matrix Test Failed Nvidia GPU Matrix Test Failed. Recoverable Severity Error Flex System x220 Compute Node Installation and Service Guide...
  • Page 179 Serviceable Automatically notify support User Response Complete the following steps: 1. Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle the system. 2. Verify that the power connectors to the GPU are connected firmly. Then power cycle the system. 3.
  • Page 180: Dsa System Management Test Results

    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power. 2. Make sure that DSA and BMC/IMM are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM Flex System x220 Compute Node Installation and Service Guide...
  • Page 181 • 166-802-001 : IMM I2C Test Aborted Test cannot be completed for unknown reason. Recoverable Severity Warning Serviceable Automatically notify support User Response Perform the actions mentioned one at a time and try the test after each action: 1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power. 2.
  • Page 182 2. Make sure that DSA and BMC/IMM are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 166-806-001 : IMM I2C Test Aborted Timeout while processing command. Flex System x220 Compute Node Installation and Service Guide...
  • Page 183 Recoverable Severity Warning Serviceable Automatically notify support User Response Perform the actions mentioned one at a time and try the test after each action: 1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power. 2.
  • Page 184 2. Make sure that DSA and BMC/IMM are at the latest level. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 166-810-001 : IMM I2C Test Aborted Request data length invalid. Recoverable Severity Warning Flex System x220 Compute Node Installation and Service Guide...
  • Page 185 Serviceable Automatically notify support User Response Perform the actions mentioned one at a time and try the test after each action: 1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power. 2. Make sure that DSA and BMC/IMM are at the latest level. Related links –...
  • Page 186 – Latest level of DSA – Latest level of BMC/IMM • 166-814-001 : IMM I2C Test Aborted Requested Sensor, data, or record not present. Recoverable Severity Warning Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 187 User Response Perform the actions mentioned one at a time and try the test after each action: 1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power. 2. Make sure that DSA and BMC/IMM are at the latest level. Related links –...
  • Page 188 Perform the actions mentioned one at a time and try the test after each action: 1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power. 2. Make sure that DSA and BMC/IMM are at the latest level. Flex System x220 Compute Node Installation and Service Guide...
  • Page 189 Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 166-819-001 : IMM I2C Test Aborted Command response could not be provided. SDR Repository in?update mode. Recoverable Severity Warning Serviceable Automatically notify support User Response Perform the actions mentioned one at a time and try the test after each action: 1.
  • Page 190 1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power. 2. Make sure that DSA and BMC/IMM are at the latest level. Related links – IBM Support website – Latest level of DSA Flex System x220 Compute Node Installation and Service Guide...
  • Page 191 – Latest level of BMC/IMM • 166-823-001 : IMM I2C Test Aborted Cannot execute command. Insufficient privilege level. Recoverable Severity Warning Serviceable Automatically notify support User Response Perform the actions mentioned one at a time and try the test after each action: 1.
  • Page 192 2. Make sure that DSA and BMC/IMM are at the latest level. 3. Run the test again. 4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action. Related links Flex System x220 Compute Node Installation and Service Guide...
  • Page 193 – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 166-904-001 : IMM I2C Test Failed IMM Indicates failure in DS2482 bus (BUS 3). Recoverable Severity Error Serviceable Automatically notify support User Response Perform the actions mentioned one at a time and try the test after each action: 1.
  • Page 194: Dsa Checkpoint Panel Test Results

    Test results for the DSA checkpoint panel test The following messages can result when you run the DSA checkpoint panel test. • 180-000-000 : Check-point Panel Test Passed Check-point Panel Test Passed. Recoverable Flex System x220 Compute Node Installation and Service Guide...
  • Page 195 Severity Event Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 180-801-000 : Check-point Panel Test Aborted Check-point Panel Test Aborted. BMC is unable to verify that the operator information panel cable is connected.
  • Page 196: Dsa Broadcom Network Test Results

    The test passed. Recoverable Severity Event Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 405-001-000 : BRCM:TestMIIRegisters Test Passed Flex System x220 Compute Node Installation and Service Guide...
  • Page 197 The test passed. Recoverable Severity Event Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 405-002-000 : BRCM:TestEEPROM Test Passed The test passed. Recoverable Severity Event Serviceable Automatically notify support Related links –...
  • Page 198 Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 405-006-000 : BRCM:TestLoopbackPhysical Test Passed The test passed. Recoverable Severity Event Flex System x220 Compute Node Installation and Service Guide...
  • Page 199 Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 405-007-000 : BRCM:TestLEDs Test Passed The test passed. Recoverable Severity Event Serviceable Automatically notify support Related links – IBM Support website –...
  • Page 200 – Latest level of DSA – Latest level of BMC/IMM • 405-803-000 : BRCM:TestInternalMemory Test Aborted The internal memory test was canceled. Recoverable Severity Warning Serviceable Automatically notify support Related links Flex System x220 Compute Node Installation and Service Guide...
  • Page 201 – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 405-804-000 : BRCM:TestInterrupt Test Aborted The interrupt test was canceled. Recoverable Severity Warning Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA –...
  • Page 202 DSA Diagnostic Event Log within the Firmware/VPD section for this component. 2. Rerun the test. 3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action. Flex System x220 Compute Node Installation and Service Guide...
  • Page 203 Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 405-901-000 : BRCM:TestMIIRegisters Test Failed A failure was detected while testing internal PHY registers. Recoverable Severity Error Serviceable Automatically notify support User Response Complete the following steps: 1.
  • Page 204 IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 405-904-000 : BRCM:TestInterrupt Test Failed A failure was detected while testing interrupts. Recoverable Severity Error Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 205 User Response Complete the following steps: 1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. 2. Rerun the test. 3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide"...
  • Page 206: Dsa Brocade Test Results

    Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM DSA Brocade test results The following messages can result when you run the Brocade test. Flex System x220 Compute Node Installation and Service Guide...
  • Page 207 Test results for the DSA Brocade test The following messages can result when you run the DSA Brocade test. • 218-000-000 : Brocade:MemoryTest Passed The test passed. Recoverable Severity Event Serviceable Automatically notify support Related links – IBM Support website –...
  • Page 208 Recoverable Severity Event Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 218-005-000 : Brocade:SerdesEthLoopbackTest Passed The test passed. Flex System x220 Compute Node Installation and Service Guide...
  • Page 209 Recoverable Severity Event Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 218-006-000 : Brocade:InternalLoopbackTest Passed The test passed. Recoverable Severity Event Serviceable Automatically notify support Related links –...
  • Page 210 Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 218-803-000 : Brocade:PCILoopbackTest Aborted The test was canceled. Recoverable Severity Warning Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 211 Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 218-804-000 : Brocade:ExternalEthLoopbackTest Aborted The test was canceled. Recoverable Severity Warning Serviceable Automatically notify support Related links – IBM Support website –...
  • Page 212 Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 218-901-000 : Brocade:ExternalLoopbackTest Failed A failure was detected during the Loopback test. Recoverable Severity Error Flex System x220 Compute Node Installation and Service Guide...
  • Page 213 Serviceable Automatically notify support User Response Complete the following steps: 1. Check cable connections. 2. Rerun the test. 3. Verify whether the firmware is at proper level. 4. Rerun the test. 5. If the problem remains, contact your IBM technical-support representative. Related links –...
  • Page 214 3. Verify whether the firmware is at proper level. 4. Rerun the test. 5. If the problem remains, contact your IBM technical-support representative. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM Flex System x220 Compute Node Installation and Service Guide...
  • Page 215 • 218-905-000 : Brocade:SerdesEthLoopbackTest Failed A failure was detected during the Loopback test. Recoverable Severity Error Serviceable Automatically notify support User Response Complete the following steps: 1. Rerun the test. 2. Verify whether the firmware is at proper level. 3. Rerun the test. 4.
  • Page 216 Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 516-002-000 : ELXUCNA: ELXUCNA: NIC LED(Beacon)Test Passed The test passed. Flex System x220 Compute Node Installation and Service Guide...
  • Page 217 Recoverable Severity Event Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 516-800-000 : ELXUCNA: NIC MAC LoopBackTest Aborted Loopback testing at the MAC layer was canceled. Recoverable Severity Warning Serviceable...
  • Page 218 3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 516-901-000 : ELXUCNA: NIC PHY LoopBackTest Failed Flex System x220 Compute Node Installation and Service Guide...
  • Page 219 A failure was detected during the loopback test at the physical layer. Recoverable Severity Error Serviceable Automatically notify support User Response Complete the following steps: 1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
  • Page 220 Event Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 408-800-000 : MLNX:MLNX_DiagnosticTestEthernetPort Test Aborted Port Test was canceled. Flex System x220 Compute Node Installation and Service Guide...
  • Page 221 Recoverable Severity Warning Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 408-801-000 : MLNX:MLNX_DiagnosticTestIBPort Test Aborted Port Test was canceled. Recoverable Severity Warning Serviceable Automatically notify support Related links –...
  • Page 222 Test results for the DSA EXA port ping test The following messages can result when you run the DSA EXA port ping test. • 401-000-000 : EXA Port Ping Test Passed EXA Port Ping Test Passed. Recoverable Severity Event Flex System x220 Compute Node Installation and Service Guide...
  • Page 223 Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 401-801-000 : EXA Port Ping Test Aborted EXA Port Ping Test Aborted. Unable to get device base address. Recoverable Severity Warning Serviceable...
  • Page 224 The following messages can result when you run the Intel network test. Test results for the DSA Intel network test The following messages can result when you run the DSA Intel network test. • 406-000-000 : IANet:Registers Test Passed Flex System x220 Compute Node Installation and Service Guide...
  • Page 225 The test passed. Recoverable Severity Event Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 406-001-000 : IANet:EEPROM Test Passed The test passed. Recoverable Severity Event Serviceable Automatically notify support Related links –...
  • Page 226 Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 406-800-000 : IANet:Registers Test Aborted Registers test was canceled. Recoverable Severity Warning Flex System x220 Compute Node Installation and Service Guide...
  • Page 227 Serviceable Automatically notify support Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 406-801-000 : IANet:EEPROM Test Aborted EEPROM test was canceled. Recoverable Severity Warning Serviceable Automatically notify support Related links – IBM Support website –...
  • Page 228 Latest level of BMC/IMM • 406-900-000 : IANet:Registers Test Failed A failure was detected during the Registers test. Recoverable Severity Error Serviceable Automatically notify support User Response Complete the following steps: Flex System x220 Compute Node Installation and Service Guide...
  • Page 229 1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. 2. Rerun the test. 3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide"...
  • Page 230 Guide" for the next corrective action. Related links – IBM Support website – Latest level of DSA – Latest level of BMC/IMM • 406-904-000 : IANet:Loopback Test Failed A failure was detected during the Loopback test. Flex System x220 Compute Node Installation and Service Guide...
  • Page 231: Event Messages

    IMM messages When a hardware event is detected by the IMM on a Flex System x220 Compute Node, the IMM logs that event in the system-event log in the compute node. In addition, the IMM sends that event to the CMM and to the Flex System Manager management software (if installed).
  • Page 232 You can configure the IBM Flex System Manager or the CMM to automatically notify Support (also known as call home) if certain types of errors are encountered. If you have configured this function, see the table for a list of events that automatically notify Support. Flex System x220 Compute Node Installation and Service Guide...
  • Page 233 Table 9. Events that automatically notify Support Automatically Event ID Message String Notify Support 40000086-00000000 Test Call Home Generated by user [arg1]. 40000087-00000000 Manual Call Home by user [arg1]: [arg2]. 80010202-0701ffff Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted. 80010202-2801ffff Sensor Planar VBAT has detected low battery voltage.
  • Page 234 Failure Predicted on drive Drive 7 for array [ComputerSystemElementName]. 806f050c-2001ffff Memory Logging Limit Reached for DIMM 1 on Subsystem [MemoryElementName]. 806f050c-2002ffff Memory Logging Limit Reached for DIMM 2 on Subsystem [MemoryElementName]. Flex System x220 Compute Node Installation and Service Guide...
  • Page 235 Table 9. Events that automatically notify Support (continued) Automatically Event ID Message String Notify Support 806f050c-2003ffff Memory Logging Limit Reached for DIMM 3 on Subsystem [MemoryElementName]. 806f050c-2004ffff Memory Logging Limit Reached for DIMM 4 on Subsystem [MemoryElementName]. 806f050c-2005ffff Memory Logging Limit Reached for DIMM 5 on Subsystem [MemoryElementName].
  • Page 236 • 40000003-00000000 : Ethernet Data Rate modified from [arg1] to [arg2] by user [arg3]. The specified user has changed the Ethernet data rate of the Integrated Management Module external network interface to the specified value. Flex System x220 Compute Node Installation and Service Guide...
  • Page 237 May also be shown as 4000000300000000 or 0x4000000300000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0003 User Response Information only; no action is required. • 40000004-00000000 : Ethernet Duplex setting modified from [arg1] to [arg2] by user [arg3]. The specified user has changed the Ethernet duplex setting of the Integrated Management Module external network interface to the specified value.
  • Page 238 Information only; no action is required. • 40000007-00000000 : Ethernet interface [arg1] by user [arg2]. The specified user has enabled or disabled the Ethernet interface. May also be shown as 4000000700000000 or 0x4000000700000000 Flex System x220 Compute Node Installation and Service Guide...
  • Page 239 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0007 User Response Information only; no action is required. • 40000008-00000000 : Hostname set to [arg1] by user [arg2]. The specified user has changed the Integrated Management Module host name. May also be shown as 4000000800000000 or 0x4000000800000000 Severity Info...
  • Page 240 • 4000000b-00000000 : IP address of default gateway modified from [arg1] to [arg2] by user [arg3]. The specified user has changed the gateway address of the Integrated Management Module external network interface to the specified value. May also be shown as 4000000b00000000 or 0x4000000b00000000 Severity Info Flex System x220 Compute Node Installation and Service Guide...
  • Page 241 Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0011 User Response Information only; no action is required. • 4000000c-00000000 : OS Watchdog response [arg1] by [arg2] . The OS Watchdog timer has been enabled of disabled by a user. May also be shown as 4000000c00000000 or 0x4000000c00000000 Severity Info...
  • Page 242 • 4000000f-00000000 : Attempting to [arg1] server [arg2] by user [arg3]. The specified user has initiated a power function on the system using the Management Controller. May also be shown as 4000000f00000000 or 0x4000000f00000000 Severity Info Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 243 Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0015 User Response Information only; no action is required. • 40000010-00000000 : Security: Userid: [arg1] had [arg2] login failures from WEB client at IP address [arg3]. A user has exceeded the maximum allowed number of unsuccessful login attempts from a web browser and has been prevented from logging in for the lockout period.
  • Page 244 [arg1] from TELNET client at IP address [arg2]. A user has attempted to log in from a Telnet session by using an invalid login ID or password. May also be shown as 4000001300000000 or 0x4000001300000000 Flex System x220 Compute Node Installation and Service Guide...
  • Page 245 Severity Info Serviceable Automatically notify support Alert Category System - Remote Login SNMP Trap ID CIM Information Prefix: IMM ID: 0019 User Response Make sure that the correct login ID and password are being used. • 40000014-00000000 : The [arg1] on system [arg2] cleared by user [arg3]. The specified user has deleted system log events or audit log events.
  • Page 246 40000017-00000000 : ENET[[arg1]] IP-Cfg:HstName=[arg2], IP@=[arg3] ,NetMsk=[arg4], GW@=[arg5] . An IMM IP address and configuration have been assigned using client data. May also be shown as 4000001700000000 or 0x4000001700000000 Severity Info Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 247 Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0023 User Response Information only; no action is required. • 40000018-00000000 : LAN: Ethernet[[arg1]] interface is no longer active. The IMM Ethernet interface has been disabled. May also be shown as 4000001800000000 or 0x4000001800000000 Severity Info...
  • Page 248 The specified user has restored the Integrated Management Module (IMM) configuration from a previously saved configuration file. Some configuration settings might require that the IMM be restarted before they take effect. May also be shown as 4000001b00000000 or 0x4000001b00000000 Severity Info Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 249 Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0027 User Response Information only; no action is required. • 4000001c-00000000 : Watchdog [arg1] Screen Capture Occurred. An operating-system error has occurred, and the screen capture was successful. May also be shown as 4000001c00000000 or 0x4000001c00000000 Severity Info...
  • Page 250 Update the IMM firmware. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code. Flex System x220 Compute Node Installation and Service Guide...
  • Page 251 • 4000001f-00000000 : Please ensure that the Management Controller [arg1] is flashed with the correct firmware. The Management Controller is unable to match its firmware to the server. The server does not support the installed IMM firmware version. May also be shown as 4000001f00000000 or 0x4000001f00000000 Severity Error Serviceable...
  • Page 252 SNMP Trap ID CIM Information Prefix: IMM ID: 0034 User Response Complete the following steps until the problem is solved: 1. Make sure that the certificate that you are importing is correct. Flex System x220 Compute Node Installation and Service Guide...
  • Page 253 2. Try to import the certificate again. • 40000023-00000000 : Flash of [arg1] from [arg2] succeeded for user [arg3] . The specified firmware update has been completed. May also be shown as 4000002300000000 or 0x4000002300000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID...
  • Page 254 System - Event Log Fullness SNMP Trap ID CIM Information Prefix: IMM ID: 0038 User Response To avoid losing older log entries, save the log as a text file and clear the log. Flex System x220 Compute Node Installation and Service Guide...
  • Page 255 • 40000027-00000000 : Platform Watchdog Timer expired for [arg1]. A Platform Watchdog Timer Expired event has occurred. May also be shown as 4000002700000000 or 0x4000002700000000 Severity Error Serviceable Automatically notify support Alert Category System - OS Timeout SNMP Trap ID CIM Information Prefix: IMM ID: 0039 User Response...
  • Page 256 A specific type of firmware mismatch has been detected. May also be shown as 4000002a00000000 or 0x4000002a00000000 Severity Error Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 257 CIM Information Prefix: IMM ID: 0042 User Response Reflash the IMM firmware to the latest version. • 4000002b-00000000 : Domain name set to [arg1]. Domain name set by user May also be shown as 4000002b00000000 or 0x4000002b00000000 Severity Info Serviceable Automatically notify support Alert Category none...
  • Page 258 May also be shown as 4000002e00000000 or 0x4000002e00000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0046 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 259 • 4000002f-00000000 : IPv6 enabled by user [arg1] . The specified user has enabled IPv6 support on the Integrated Management Module. May also be shown as 4000002f00000000 or 0x4000002f00000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0047 User Response...
  • Page 260 Information only; no action is required. • 40000033-00000000 : IPv6 stateless auto-configuration enabled by user [arg1]. IPv6 stateless address auto-configuration has been enabled on the Integrated Management Module by the specified user. Flex System x220 Compute Node Installation and Service Guide...
  • Page 261 May also be shown as 4000003300000000 or 0x4000003300000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0051 User Response Information only; no action is required. • 40000034-00000000 : IPv6 static IP configuration disabled by user [arg1]. The specified user has disabled IPv6 static address assignment on the Integrated Management Module.
  • Page 262 User Response Information only; no action is required. • 40000037-00000000 : ENET[[arg1]] IPv6-LinkLocal:HstName=[arg2], IP@=[arg3], Pref=[arg4] . The IPv6 link-local address is active. May also be shown as 4000003700000000 or 0x4000003700000000 Severity Info Flex System x220 Compute Node Installation and Service Guide...
  • Page 263 Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0055 User Response Information only; no action is required. • 40000038-00000000 : ENET[[arg1]] IPv6-Static:HstName=[arg2], IP@=[arg3], Pref=[arg4], GW@=[arg5]. The IPv6 static address is active. May also be shown as 4000003800000000 or 0x4000003800000000 Severity Info Serviceable...
  • Page 264 4000003b-00000000 : DHCPv6 failure, no IP address assigned. The DHCPv6 server has failed to assign an IP address to a management controller. May also be shown as 4000003b00000000 or 0x4000003b00000000 Severity Warning Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 265 Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0059 User Response Complete the following steps until the problem is solved: 1. Make sure that the IMM network cable is connected. 2. Make sure that there is a DHCPv6 server on the network that can assign an IP address to the IMM.
  • Page 266 • 4000003f-00000000 : Web-HTTP port number changed from [arg1] to [arg2] by user [arg3]. The specified user has changed the HTTP port number. New HTTP (web) connections must use the new port number. May also be shown as 4000003f00000000 or 0x4000003f00000000 Severity Info Flex System x220 Compute Node Installation and Service Guide...
  • Page 267 Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0063 User Response Information only; no action is required. • 40000040-00000000 : Web-HTTPS port number changed from [arg1] to [arg2] by user [arg3]. The specified user has changed the HTTPS port number. New HTTPS (secure web) connections must use the new port number.
  • Page 268 • 40000043-00000000 : SNMP Agent port number changed from [arg1] to [arg2] by user [arg3]. The specified user has changed the Simple Network Management Protocol (SNMP) agent port number. May also be shown as 4000004300000000 or 0x4000004300000000 Severity Info Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 269 Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0067 User Response Information only; no action is required. • 40000044-00000000 : SNMP Traps port number changed from [arg1] to [arg2] by user [arg3]. The specified user has changed the Simple Network Management Protocol (SNMP) traps port number. May also be shown as 4000004400000000 or 0x4000004400000000 Severity Info...
  • Page 270 • 40000047-00000000 : LED [arg1] state changed to [arg2] by [arg3]. The specified LED has changed state. May also be shown as 4000004700000000 or 0x4000004700000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 271 CIM Information Prefix: IMM ID: 0071 User Response Information only; no action is required. • 40000048-00000000 : Inventory data changed for device [arg1], new device data hash=[arg2], new master data hash=[arg3] . Something has caused the physical inventory to change May also be shown as 4000004800000000 or 0x4000004800000000 Severity Info...
  • Page 272 May also be shown as 4000004b00000000 or 0x4000004b00000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0075 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 273 • 4000004c-00000000 : LDAP Server configuration set by user [arg1]: SelectionMethod=[arg2], DomainName=[arg3], Server1=[arg4], Server2=[arg5], Server3=[arg6], Server4=[arg7]. A user changed the LDAP server configuration May also be shown as 4000004c00000000 or 0x4000004c00000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0076...
  • Page 274 May also be shown as 4000004f00000000 or 0x4000004f00000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0079 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 275 • 40000050-00000000 : Server General Settings set by user [arg1]: Name=[arg2], Contact=[arg3], Location=[arg4], Room=[arg5], RackID=[arg6], Rack U-position=[arg7]. A user configured the Location setting May also be shown as 4000005000000000 or 0x4000005000000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0080...
  • Page 276 Information only; no action is required. • 40000054-00000000 : Server [arg1] [arg2] cleared by user [arg3]. A user cleared a Server Power Action. May also be shown as 4000005400000000 or 0x4000005400000000 Flex System x220 Compute Node Installation and Service Guide...
  • Page 277 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0084 User Response Information only; no action is required. • 40000055-00000000 : Synchronize time setting by user [arg1]: Mode=[arg2], NTPServerHost=[arg3]:[arg4],NTPUpdateFrequency=[arg5]. A user configured the Date and Time synchronize settings May also be shown as 4000005500000000 or 0x4000005500000000 Severity Info...
  • Page 278 40000058-00000000 : DNS servers set by user [arg1]: UseAdditionalServers=[arg2], PreferredDNStype=[arg3], IPv4Server1=[arg4], IPv4Server2=[arg5], IPv4Server3=[arg6], IPv6Server1=[arg7], IPv6Server2=[arg8], IPv6Server3=[arg9]. The specified user has configured the DNS servers. May also be shown as 4000005800000000 or 0x4000005800000000 Severity Flex System x220 Compute Node Installation and Service Guide...
  • Page 279 Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0088 User Response Information only; no action is required. • 40000059-00000000 : LAN over USB [arg1] by user [arg2]. A user configured USB-LAN May also be shown as 4000005900000000 or 0x4000005900000000 Severity Info Serviceable...
  • Page 280 Information only; no action is required. • 4000005c-00000000 : Secure CIM/XML(HTTPS) [arg1] by user [arg2]. The secure CIM-XML port has been enabled or disabled. May also be shown as 4000005c00000000 or 0x4000005c00000000 Severity Info Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 281 Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0092 User Response Information only; no action is required. • 4000005d-00000000 : Secure LDAP [arg1] by user [arg2]. A user enables or disables Secure LDAP services May also be shown as 4000005d00000000 or 0x4000005d00000000 Severity Info...
  • Page 282 A Integrated Management Module license that allows access to the specified feature was added to the system. May also be shown as 4000006000000000 or 0x4000006000000000 Severity Info Serviceable Automatically notify support Alert Category Flex System x220 Compute Node Installation and Service Guide...
  • Page 283 none SNMP Trap ID CIM Information Prefix: IMM ID: 0096 User Response Information only; no action is required. • 40000061-00000000 : License key for [arg1] removed by user [arg2]. The specified user has removed an Integrated Management Module license. Access to the specified feature is no longer allowed.
  • Page 284 Information only; no action is required. • 40000064-00000000 : User [arg1] created. A user account has been created. May also be shown as 4000006400000000 or 0x4000006400000000 Severity Info Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 285 Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0100 User Response Information only; no action is required. • 40000065-00000000 : User [arg1] removed. A user account has been removed. May also be shown as 4000006500000000 or 0x4000006500000000 Severity Info Serviceable...
  • Page 286 40000068-00000000 : User [arg1] custom privileges set: [arg2]. User account priveleges assigned May also be shown as 4000006800000000 or 0x4000006800000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 287 CIM Information Prefix: IMM ID: 0104 User Response Information only; no action is required. • 40000069-00000000 : User [arg1] for SNMPv3 set: AuthenticationProtocol=[arg2], PrivacyProtocol=[arg3], AccessType=[arg4], HostforTraps=[arg5]. User account SNMPv3 settings changed May also be shown as 4000006900000000 or 0x4000006900000000 Severity Info Serviceable Automatically notify support...
  • Page 288 May also be shown as 4000006c00000000 or 0x4000006c00000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0108 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 289 • 4000006d-00000000 : Management Controller [arg1]: Configuration saved to a file by user [arg2]. A user saves a Management Controller configuration to a file. May also be shown as 4000006d00000000 or 0x4000006d00000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information...
  • Page 290 CIM Information Prefix: IMM ID: 0112 User Response Information only; no action is required. • 40000071-00000000 : The power cap value changed from [arg1] watts to [arg2] watts by user [arg3]. Flex System x220 Compute Node Installation and Service Guide...
  • Page 291 The power capping level has been changed. May also be shown as 4000007100000000 or 0x4000007100000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0113 User Response Information only; no action is required •...
  • Page 292 • 40000075-00000000 : The measured power value exceeded the power cap value. The measured power value has exceeded the power cap value. May also be shown as 4000007500000000 or 0x4000007500000000 Severity Flex System x220 Compute Node Installation and Service Guide...
  • Page 293 Warning Serviceable Automatically notify support Alert Category Warning - Power SNMP Trap ID CIM Information Prefix: IMM ID: 0117 User Response – Make sure IMM firmware is at the latest level. – Raise the system power cap value or adjust the system workload to be less than the currently applied power cap.
  • Page 294 • 40000079-00000000 : Static Power Savings mode has been turned on by user [arg1]. Static Power Savings mode turned on by user May also be shown as 4000007900000000 or 0x4000007900000000 Severity Info Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 295 Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0121 User Response Information only; no action is required. • 4000007a-00000000 : Static Power Savings mode has been turned off by user [arg1]. Static Power Savings mode turned off by user May also be shown as 4000007a00000000 or 0x4000007a00000000 Severity Info...
  • Page 296 • 4000007d-00000000 : Power cap and external throttling occurred. Power cap and external throttling has occurred. May also be shown as 4000007d00000000 or 0x4000007d00000000 Severity Info Serviceable Automatically notify support Alert Category Flex System x220 Compute Node Installation and Service Guide...
  • Page 297 none SNMP Trap ID CIM Information Prefix: IMM ID: 0125 User Response Information only; no action is required. • 4000007e-00000000 : External throttling occurred . External throttling has occurred. May also be shown as 4000007e00000000 or 0x4000007e00000000 Severity Info Serviceable Automatically notify support Alert Category none...
  • Page 298 40000081-00000000 : PXE boot requested by user [arg1]. PXE boot requested May also be shown as 4000008100000000 or 0x4000008100000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Flex System x220 Compute Node Installation and Service Guide...
  • Page 299 Prefix: IMM ID: 0129 User Response Information only; no action is required. • 40000082-00000000 : The measured power value has returned below the power cap value. The measured power value has returned below the power cap value. May also be shown as 4000008200000000 or 0x4000008200000000 Severity Info Serviceable...
  • Page 300 Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: IMM ID: 0133 User Response Attempt to flash the FPGA firmware to the same level on all nodes. Flex System x220 Compute Node Installation and Service Guide...
  • Page 301 • 40000086-00000000 : Test Call Home Generated by user [arg1]. The specified user has generated a test automatic support notification. May also be shown as 4000008600000000 or 0x4000008600000000 Severity Info Serviceable Automatically notify support Alert Category none SNMP Trap ID CIM Information Prefix: IMM ID: 0134 User Response...
  • Page 302 1. Turn off the server and disconnect it from the power source. You must disconnect the server from ac power to reset the IMM. 2. After 45 seconds, reconnect the server to the power source and turn on the server. Flex System x220 Compute Node Installation and Service Guide...
  • Page 303 3. Retry the operation • 4000008a-00000000 : Management Controller [arg1]: Configuration restoration from a file by user [arg2] failed to start. Restoration of the configuration of the specified management controller from a file by the specified user has failed to start. May also be shown as 4000008a00000000 or 0x4000008a00000000 Severity Error...
  • Page 304 A user has attempted to log in from a CIM client by using an invalid login ID or password. May also be shown as 4000008d00000000 or 0x4000008d00000000 Severity Info Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 305 Alert Category System - Remote Login SNMP Trap ID CIM Information Prefix: IMM ID: 0141 User Response Make sure that the correct login ID and password are being used. • 80010202-0701ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
  • Page 306 • 80010701-3702ffff : Numeric sensor PEN Inlet Temp going high (upper non-critical) has asserted. The PEN inlet temperature has exceeded its specified threshold. The compute node has attempted a soft shutdown. May also be shown as 800107013702ffff or 0x800107013702ffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 307 Severity Warning Serviceable Automatically notify support Alert Category Warning - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0490 User Response Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
  • Page 308 • 80010902-0701ffff : Sensor [NumericSensorElementName] has detected high voltage. A voltage has exceeded its specified threshold. May also be shown as 800109020701ffff or 0x800109020701ffff Severity Error Serviceable Automatically notify support Alert Category Flex System x220 Compute Node Installation and Service Guide...
  • Page 309 Critical - Voltage SNMP Trap ID CIM Information Prefix: PLAT ID: 0494 User Response Use one of the following procedures: – If the specified sensor is Planar 3.3V or Planar 5V, replace the system board. – If the specified sensor is Planar 12V, check the Chassis Management Module or Flex System Manager event log for power-supply-related issues, and resolve those issues.
  • Page 310 User Response Information only; no action is required. • 8003010e-2581ffff : Sensor Memory Resized has asserted. This message is for the use case when an implementation has detected a sensor has asserted. Flex System x220 Compute Node Installation and Service Guide...
  • Page 311 May also be shown as 8003010e2581ffff or 0x8003010e2581ffff Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0508 User Response This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 312 The temperature of the I/O expansion adapter in I/O expansion connector 1 has exceeded its specified threshold. May also be shown as 800701012c01ffff or 0x800701012c01ffff Severity Warning Serviceable Automatically notify support Alert Category Warning - Temperature SNMP Trap ID CIM Information Flex System x220 Compute Node Installation and Service Guide...
  • Page 313 Prefix: PLAT ID: 0520 User Response Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 314 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed. 3. Make sure that the room temperature is within operating specifications. Flex System x220 Compute Node Installation and Service Guide...
  • Page 315 • 80070101-3101ffff : Sensor PCIE 1 Overtemp has transitioned from normal to non-critical state. The temperature of the PCI expansion unit PCIe Card1 has exceeded its specified threshold. May also be shown as 800701013101ffff or 0x800701013101ffff Severity Warning Serviceable Automatically notify support Alert Category Warning - Temperature SNMP Trap ID...
  • Page 316 The temperature of the PCI expansion unit PCIe Card4 has exceeded its specified threshold. May also be shown as 800701013104ffff or 0x800701013104ffff Severity Warning Serviceable Automatically notify support Alert Category Warning - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0520 Flex System x220 Compute Node Installation and Service Guide...
  • Page 317 User Response Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed. 3.
  • Page 318 • 80070201-3101ffff : Sensor PCIE 1 Overtemp has transitioned to critical from a less severe state. The temperature of the PCI expansion unit PCIe Card1 has exceeded its specified threshold. May also be shown as 800702013101ffff or 0x800702013101ffff Severity Error Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 319 Automatically notify support Alert Category Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0522 User Response Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 320 3. Make sure that the room temperature is within operating specifications. • 80070202-0701ffff : Sensor Planar Fault has gone to Critical state from a less severe state. A failure has been detected in the system board. Flex System x220 Compute Node Installation and Service Guide...
  • Page 321 May also be shown as 800702020701ffff or 0x800702020701ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Voltage SNMP Trap ID CIM Information Prefix: PLAT ID: 0522 User Response Complete the following steps: 1. Remove any recently installed components. 2.
  • Page 322 • 80070214-2201ffff : Sensor TPM Lock has deasserted the transition from normal to non-critical state. The TPM Lock has returned to normal. May also be shown as 800702142201ffff or 0x800702142201ffff Severity Error Flex System x220 Compute Node Installation and Service Guide...
  • Page 323 Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0522 User Response Information only; no action required. • 80070217-0b05ffff : Sensor ETE Fault has transitioned to critical from a less severe state. A failure has been detected in the interposer card.
  • Page 324 LPR in the base planar in the PEN, and verify if this alert has been cleared. If this alert continues to occur, then replace the LPR. If after replacing the LPR, the alert continues to occur, then replace the base planar on the PEN. Flex System x220 Compute Node Installation and Service Guide...
  • Page 325 • 80070217-2c01ffff : Sensor Mezz Exp 1 Fault has transitioned to critical from a less severe state. A problem has been detected in the I/O expansion adapter in I/O expansion connector 1. The adapter is unable to initialize. May also be shown as 800702172c01ffff or 0x800702172c01ffff Severity Error Serviceable...
  • Page 326 May also be shown as 800702172c03ffff or 0x800702172c03ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0522 User Response Flex System x220 Compute Node Installation and Service Guide...
  • Page 327 Complete the following steps: 1. Remove any recently installed components from the PCI expansion unit. 2. Try to power on the chassis. – If the chassis successfully powers on, complete the following steps: a. Check the ServerProven website to make sure that recently installed components are compatible with the chassis.
  • Page 328 • 80070217-3102ffff : Sensor PEN Slot2 Empty has transitioned to critical from a less severe state. PCIe adapter slot 2 in the PCI expansion unit is empty. May also be shown as 800702173102ffff or 0x800702173102ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Other Flex System x220 Compute Node Installation and Service Guide...
  • Page 329 SNMP Trap ID CIM Information Prefix: PLAT ID: 0522 User Response PCIe adapter slot 2 in the PCI expansion unit must not be empty. Install either a PCIe adapter or a filler in this slot. If a baffle or PCIe adapter card is installed in the slot, remove the riser and reseat the card, then reinstall the riser into the PEN to clear the critical error.
  • Page 330 Then, in the information center, open the topic for the UEFI diagnostic code and follow the instructions under "User response." • 8007021b-0301ffff : Sensor CPU 1 QPILinkErr has transitioned to critical from a less severe state. CPU 1 QPI Link Failure detected. Flex System x220 Compute Node Installation and Service Guide...
  • Page 331 May also be shown as 8007021b0301ffff or 0x8007021b0301ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0522 User Response This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 332 The temperature of microprocessor 2 has exceeded its specified threshold, causing a hard shutdown of the compute node. May also be shown as 8007030103020100 or 0x8007030103020100 Severity Error Serviceable Automatically notify support Alert Category Flex System x220 Compute Node Installation and Service Guide...
  • Page 333 Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0524 User Response Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2.
  • Page 334 The temperature of the PEN MEzzanine Expansion adapter in I/O expansion connector 3 has exceeded its specified threshold. The compute node has attempted a soft shutdown. May also be shown as 800703012c03ffff or 0x800703012c03ffff Severity Error Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 335 Alert Category Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0524 User Response Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
  • Page 336 Sensor PCIE 2 Overtemp has transitioned to critical from a less severe state. The compute node has attempted a soft shutdown. May also be shown as 800703013102ffff or 0x800703013102ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Temperature SNMP Trap ID CIM Information Flex System x220 Compute Node Installation and Service Guide...
  • Page 337 Prefix: PLAT ID: 0524 User Response Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 338 • 80070319-2201ffff : Sensor S3 Resume Fail has transitioned to non-recoverable from a less severe state. The S3 Resume Fail sesor has transitioned to non-recoverable from less severe. May also be shown as 800703192201ffff or 0x800703192201ffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 339 Severity Error Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0524 User Response This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 340 SNMP Trap ID CIM Information Prefix: PLAT ID: 0526 User Response Information only; no action is required. • 80070401-2c04ffff : Sensor PEN MExp 4 has transitioned to non-critical from a more severe state. Flex System x220 Compute Node Installation and Service Guide...
  • Page 341 The previously high temperature of the PEN Mezzanine Expansion adapter in I/O expansion connector 4 has returned to below its specified threshold. May also be shown as 800704012c04ffff or 0x800704012c04ffff Severity Warning Serviceable Automatically notify support Alert Category Warning - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0526...
  • Page 342 The temperature of the PEN Mezzanine Expansion adapter in I/O expansion connector 3 has exceeded its specified threshold. The compute node has attempted a soft shutdown. May also be shown as 800706012c03ffff or 0x800706012c03ffff Severity Error Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 343 Alert Category Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0530 User Response Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
  • Page 344 This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Flex System x220 Compute Node Installation and Service Guide...
  • Page 345 • 80080017-0f01ffff : Device SAS BP has been removed from unit [PhysicalPackageElementName]. The SAS backplane has been removed. May also be shown as 800800170f01ffff or 0x800800170f01ffff Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0537 User Response...
  • Page 346 Information only; no action is required. • 8009010c-0701ffff : Device Performance mode has been enabled. The user has switched from Acoustic mode to Performance mode. May also be shown as 8009010c0701ffff or 0x8009010c0701ffff Severity Info Flex System x220 Compute Node Installation and Service Guide...
  • Page 347 Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0538 User Response Information only; no action is required. • 80090112-2101ffff : Device [LogicalDeviceElementName] has been enabled. An IPMI or SNMP Account has been enabled. May also be shown as 800901122101ffff or 0x800901122101ffff Severity Info...
  • Page 348 • 800b050c-2581ffff : Non-redundant:Insufficient Resources for Backup Memory has asserted. This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient Resources. May also be shown as 800b050c2581ffff or 0x800b050c2581ffff Severity Flex System x220 Compute Node Installation and Service Guide...
  • Page 349 Error Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0810 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes."...
  • Page 350 "Finding the UEFI diagnostic code" under "UEFI diagnostic codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the instructions under "User response." • 806f0009-0701ffff : [PowerSupplyElementName] has been turned off. Flex System x220 Compute Node Installation and Service Guide...
  • Page 351 The compute node has been powered off. May also be shown as 806f00090701ffff or 0x806f00090701ffff Severity Info Serviceable Automatically notify support Alert Category System - Power Off SNMP Trap ID CIM Information Prefix: PLAT ID: 0106 User Response Information only; no action is required. •...
  • Page 352 Information only; no action is required. • 806f000d-0403ffff : The Drive Drive 3 has been added. Hard disk drive 3 has been installed. May also be shown as 806f000d0403ffff or 0x806f000d0403ffff Severity Flex System x220 Compute Node Installation and Service Guide...
  • Page 353 Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0162 User Response Information only; no action is required. • 806f000d-0404ffff : The Drive Drive 4 has been added. Hard disk drive 4 has been installed. May also be shown as 806f000d0404ffff or 0x806f000d0404ffff Severity Info...
  • Page 354 • 806f000d-0407ffff : The Drive Drive 7 has been added. Hard disk drive 7 has been installed. May also be shown as 806f000d0407ffff or 0x806f000d0407ffff Severity Info Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 355 Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0162 User Response Information only; no action is required. • 806f000f-220101ff : The System [ComputerSystemElementName] has detected no memory in the system. This message is for the use case when an implementation has detected that memory was detected in the system.
  • Page 356 • 806f000f-220104ff : The System [ComputerSystemElementName]has encountered a motherboard failure. This message is for the use case when an implementation has detected that a fatal motherboard failure in the system. ABR Status. Firmware Error. Flex System x220 Compute Node Installation and Service Guide...
  • Page 357 May also be shown as 806f000f220104ff or 0x806f000f220104ff Severity Error Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0795 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code"...
  • Page 358 Firmware BIOS (ROM) corruption was detected on the system during POST. ABR Status. Firmware Error. May also be shown as 806f000f22010bff or 0x806f000f22010bff Severity Error Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0850 Flex System x220 Compute Node Installation and Service Guide...
  • Page 359 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the instructions under "User response."...
  • Page 360 This message is for the use case when an implementation has detected a Fault in a slot. No Op ROM Space. May also be shown as 806f002122010900 or 0x806f002122010900 Severity Error Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 361 Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0330 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes."...
  • Page 362 "Finding the UEFI diagnostic code" under "UEFI diagnostic codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the instructions under "User response." Flex System x220 Compute Node Installation and Service Guide...
  • Page 363 • 806f0021-25820903 : Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName]. This message is for the use case when an implementation has detected a Fault in a slot. All PCI Error. One of PCI Error. May also be shown as 806f002125820903 or 0x806f002125820903 Severity Error Serviceable...
  • Page 364 TPM initialization or start up commands have failed. May also be shown as 806f00282101ffff or 0x806f00282101ffff Severity Warning Serviceable Automatically notify support Alert Category Warning - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0398 Flex System x220 Compute Node Installation and Service Guide...
  • Page 365 User Response 1. Reboot the system. 2. If error persists, or boot is unsuccessful, (Trained service technician only) Replace the system board.. • 806f0107-0301ffff : An Over-Temperature Condition has been detected on [ProcessorElementName]. The temperature of microprocessor 1 has exceeded the critical level, causing a hard shutdown of the compute node.
  • Page 366 Severity Error Serviceable Automatically notify support Alert Category Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0036 User Response Complete the following steps until the problem is solved: Flex System x220 Compute Node Installation and Service Guide...
  • Page 367 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed. 3.
  • Page 368 • 806f010c-2003ffff : Uncorrectable error detected for DIMM 3 on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected a Memory uncorrectable error. May also be shown as 806f010c2003ffff or 0x806f010c2003ffff Severity Error Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 369 Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0138 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes."...
  • Page 370 • 806f010c-2007ffff : Uncorrectable error detected for DIMM 7 on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected a Memory uncorrectable error. May also be shown as 806f010c2007ffff or 0x806f010c2007ffff Severity Error Flex System x220 Compute Node Installation and Service Guide...
  • Page 371 Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0138 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes."...
  • Page 372 Then, in the information center, open the topic for the UEFI diagnostic code and follow the instructions under "User response." • 806f010c-200bffff : Uncorrectable error detected for DIMM 11 on Subsystem [MemoryElementName]. Flex System x220 Compute Node Installation and Service Guide...
  • Page 373 This message is for the use case when an implementation has detected a Memory uncorrectable error. May also be shown as 806f010c200bffff or 0x806f010c200bffff Severity Error Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0138 User Response This is a UEFI detected event.
  • Page 374 The hard disk drive controller has detected a fault in hard disk drive 0. Hard disk drive 0 is now defunct. May also be shown as 806f010d0400ffff or 0x806f010d0400ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Hard Disk drive SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 375 CIM Information Prefix: PLAT ID: 0164 User Response Complete the following steps until the problem is solved: 1. Check the Support Portal for service bulletins and RETAIN tips related to your drive. 2. Check the Support Portal for firmware updates related to your drive. 3.
  • Page 376 2. Check the Support Portal for firmware updates related to your drive. 3. Replace the drive. 4. Check for any other RAID-related errors. • 806f010d-0404ffff : The Drive Drive 4 has been disabled due to a detected fault. Flex System x220 Compute Node Installation and Service Guide...
  • Page 377 The hard disk drive controller has detected a fault in hard disk drive 4. Hard disk drive 4 is now defunct. May also be shown as 806f010d0404ffff or 0x806f010d0404ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Hard Disk drive SNMP Trap ID CIM Information Prefix: PLAT ID: 0164...
  • Page 378 The hard disk drive controller has detected a fault in hard disk drive 7. Hard disk drive 7 is now defunct. May also be shown as 806f010d0407ffff or 0x806f010d0407ffff Severity Error Serviceable Automatically notify support Alert Category Flex System x220 Compute Node Installation and Service Guide...
  • Page 379 Critical - Hard Disk drive SNMP Trap ID CIM Information Prefix: PLAT ID: 0164 User Response Complete the following steps until the problem is solved: 1. Check the Support Portal for service bulletins and RETAIN tips related to your drive. 2.
  • Page 380 CPU 2 PECI : • 806f011b-0c01ffff : The connector LightPath has encountered a configuration error. The light path LED card is not detected. May also be shown as 806f011b0c01ffff or 0x806f011b0c01ffff Severity Error Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 381 Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0266 User Response Complete the following steps until the problem is solved: 1. Make sure that the cable from the light path LED card to the system board is securely connected. 2.
  • Page 382 • 806f0207-0302ffff : CPU 2 has Failed with FRB1/BIST condition. This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST condition. May also be shown as 806f02070302ffff or 0x806f02070302ffff Severity Error Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 383 Automatically notify support Alert Category Critical - CPU SNMP Trap ID CIM Information Prefix: PLAT ID: 0044 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes."...
  • Page 384 • 806f020d-0402ffff : Failure Predicted on drive Drive 2 for array [ComputerSystemElementName]. This message is for the use case when an implementation has detected an Array Failure is Predicted. May also be shown as 806f020d0402ffff or 0x806f020d0402ffff Severity Warning Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 385 Automatically notify support Alert Category System - Predicted Failure SNMP Trap ID CIM Information Prefix: PLAT ID: 0168 User Response Replace hard disk drive 2 at the next maintenance period. • 806f020d-0403ffff : Failure Predicted on drive Drive 3 for array [ComputerSystemElementName]. This message is for the use case when an implementation has detected an Array Failure is Predicted.
  • Page 386 This message is for the use case when an implementation has detected an Array Failure is Predicted. May also be shown as 806f020d0406ffff or 0x806f020d0406ffff Severity Warning Serviceable Automatically notify support Alert Category Flex System x220 Compute Node Installation and Service Guide...
  • Page 387 System - Predicted Failure SNMP Trap ID CIM Information Prefix: PLAT ID: 0168 User Response Replace hard disk drive 6 at the next maintenance period. • 806f020d-0407ffff : Failure Predicted on drive Drive 7 for array [ComputerSystemElementName]. This message is for the use case when an implementation has detected an Array Failure is Predicted. May also be shown as 806f020d0407ffff or 0x806f020d0407ffff Severity Warning...
  • Page 388 • 806f030c-2002ffff : Scrub Failure for DIMM 2 on Subsystem [MemoryElementName]. Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c2002ffff or 0x806f030c2002ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 389 CIM Information Prefix: PLAT ID: 0136 User Response This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 390 • 806f030c-2006ffff : Scrub Failure for DIMM 6 on Subsystem [MemoryElementName]. Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c2006ffff or 0x806f030c2006ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Memory Flex System x220 Compute Node Installation and Service Guide...
  • Page 391 SNMP Trap ID CIM Information Prefix: PLAT ID: 0136 User Response This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 392 • 806f030c-200affff : Scrub Failure for DIMM 10 on Subsystem [MemoryElementName]. Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c200affff or 0x806f030c200affff Severity Error Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 393 Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0136 User Response This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 394 • 806f0313-1701ffff : A software NMI has occurred on system [ComputerSystemElementName]. A software NMI has occurred. The compute node might have restarted, depending on the configuration setting. May also be shown as 806f03131701ffff or 0x806f03131701ffff Severity Error Flex System x220 Compute Node Installation and Service Guide...
  • Page 395 Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0228 User Response Check the operating-system logs and resolve any issues related the NMI. • 806f0323-2101ffff : Power cycle of system [ComputerSystemElementName] initiated by watchdog IPMI Watchdog.
  • Page 396 • 806f040c-2003ffff : DIMM 3 Disabled on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected that Memory has been Disabled. May also be shown as 806f040c2003ffff or 0x806f040c2003ffff Severity Info Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 397 Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0131 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes."...
  • Page 398 • 806f040c-2007ffff : DIMM 7 Disabled on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected that Memory has been Disabled. May also be shown as 806f040c2007ffff or 0x806f040c2007ffff Severity Flex System x220 Compute Node Installation and Service Guide...
  • Page 399 Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0131 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes."...
  • Page 400 • 806f040c-200bffff : DIMM 11 Disabled on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected that Memory has been Disabled. May also be shown as 806f040c200bffff or 0x806f040c200bffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 401 Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0131 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code"...
  • Page 402 Then, in the information center, open the topic for the UEFI diagnostic code and follow the instructions under "User response." • 806f0413-2c03ffff : A PCI PERR has occurred on system [ComputerSystemElementName]. Flex System x220 Compute Node Installation and Service Guide...
  • Page 403 A PCI parity error has been detected in the I/O expansion adapter in PCIe adapter slot 3 in the PCI expansion unit. May also be shown as 806f04132c03ffff or 0x806f04132c03ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0232...
  • Page 404 A PCI parity error has been detected in the I/O expansion adapter in PCIe adapter slot 1 in the PCI expansion unit. May also be shown as 806f04133102ffff or 0x806f04133102ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 405 CIM Information Prefix: PLAT ID: 0232 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the instructions under "User response."...
  • Page 406 806f0507-0302ffff : CPU 2 has a Configuration Mismatch. This message is for the use case when an implementation has detected a Processor Configuration Mismatch has occurred. May also be shown as 806f05070302ffff or 0x806f05070302ffff Severity Error Flex System x220 Compute Node Installation and Service Guide...
  • Page 407 Serviceable Automatically notify support Alert Category Critical - CPU SNMP Trap ID CIM Information Prefix: PLAT ID: 0062 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes."...
  • Page 408 "Finding the UEFI diagnostic code" under "UEFI diagnostic codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the instructions under "User response." Flex System x220 Compute Node Installation and Service Guide...
  • Page 409 • 806f050c-2003ffff : Memory Logging Limit Reached for DIMM 3 on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached. May also be shown as 806f050c2003ffff or 0x806f050c2003ffff Severity Warning Serviceable...
  • Page 410 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached. May also be shown as 806f050c2006ffff or 0x806f050c2006ffff Severity Warning Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 411 Alert Category Warning - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0144 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes."...
  • Page 412 Then, in the information center, open the topic for the UEFI diagnostic code and follow the instructions under "User response." • 806f050c-200affff : Memory Logging Limit Reached for DIMM 10 on Subsystem [MemoryElementName]. Flex System x220 Compute Node Installation and Service Guide...
  • Page 413 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached. May also be shown as 806f050c200affff or 0x806f050c200affff Severity Warning Serviceable Automatically notify support Alert Category Warning - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0144 User Response...
  • Page 414 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached. All DIMMs. One of the DIMMs. May also be shown as 806f050c2581ffff or 0x806f050c2581ffff Severity Warning Serviceable Automatically notify support Alert Category Flex System x220 Compute Node Installation and Service Guide...
  • Page 415 Warning - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0144 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes."...
  • Page 416 The RAID array is in critical condition. Immediate action is required to avoid a system outage. May also be shown as 806f050d0403ffff or 0x806f050d0403ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Hard Disk drive SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 417 CIM Information Prefix: PLAT ID: 0174 User Response Replace the hard disk drive that is indicated by a lit status LED. • 806f050d-0404ffff : Array [ComputerSystemElementName] is in critical condition. The RAID array is in critical condition. Immediate action is required to avoid a system outage. May also be shown as 806f050d0404ffff or 0x806f050d0404ffff Severity Error...
  • Page 418 May also be shown as 806f050d0407ffff or 0x806f050d0407ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Hard Disk drive SNMP Trap ID CIM Information Prefix: PLAT ID: 0174 User Response Flex System x220 Compute Node Installation and Service Guide...
  • Page 419 Replace the hard disk drive that is indicated by a lit status LED. • 806f0513-2582ffff : A PCI SERR has occurred on system [ComputerSystemElementName]. This message is for the use case when an implementation has detected a PCI SERR, PCIs. May also be shown as 806f05132582ffff or 0x806f05132582ffff Severity Error...
  • Page 420 A PCI system error has been detected in the I/O expansion adapter in PCIe adapter slot 1 in the PCI expansion unit. May also be shown as 806f05133101ffff or 0x806f05133101ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Other Flex System x220 Compute Node Installation and Service Guide...
  • Page 421 SNMP Trap ID CIM Information Prefix: PLAT ID: 0234 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes."...
  • Page 422 806f052b-2101ffff : Invalid or Unsupported firmware or software was detected on system [ComputerSystemElementName]. The IMM primary firmware image has been corrupted. The IMM is running on the backup image. May also be shown as 806f052b2101ffff or 0x806f052b2101ffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 423 Severity Error Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0446 User Response Reflash or update the IMM firmware. • 806f0607-0301ffff : An SM BIOS Uncorrectable CPU complex error for CPU 1 has asserted. This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.
  • Page 424 "Finding the UEFI diagnostic code" under "UEFI diagnostic codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the instructions under "User response." • 806f060d-0400ffff : Array [ComputerSystemElementName] has failed. Flex System x220 Compute Node Installation and Service Guide...
  • Page 425 The RAID array has failed. May also be shown as 806f060d0400ffff or 0x806f060d0400ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Hard Disk drive SNMP Trap ID CIM Information Prefix: PLAT ID: 0176 User Response Complete the following steps: –...
  • Page 426 Critical - Hard Disk drive SNMP Trap ID CIM Information Prefix: PLAT ID: 0176 User Response Complete the following steps: – Replace any hard disk drive that is indicated by a lit status LED. Flex System x220 Compute Node Installation and Service Guide...
  • Page 427 – Re-create the array. – Restore the data from a backup. • 806f060d-0404ffff : Array [ComputerSystemElementName] has failed. The RAID array has failed. May also be shown as 806f060d0404ffff or 0x806f060d0404ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Hard Disk drive SNMP Trap ID CIM Information Prefix: PLAT ID: 0176...
  • Page 428 • 806f060d-0407ffff : Array [ComputerSystemElementName] has failed. The RAID array has failed. May also be shown as 806f060d0407ffff or 0x806f060d0407ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Hard Disk drive SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 429 CIM Information Prefix: PLAT ID: 0176 User Response Complete the following steps: – Replace any hard disk drive that is indicated by a lit status LED. – Re-create the array. – Restore the data from a backup. • 806f070c-2001ffff : Configuration Error for DIMM 1 on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.
  • Page 430 • 806f070c-2004ffff : Configuration Error for DIMM 4 on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected. May also be shown as 806f070c2004ffff or 0x806f070c2004ffff Severity Error Flex System x220 Compute Node Installation and Service Guide...
  • Page 431 Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0126 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes."...
  • Page 432 Then, in the information center, open the topic for the UEFI diagnostic code and follow the instructions under "User response." • 806f070c-2008ffff : Configuration Error for DIMM 8 on Subsystem [MemoryElementName]. Flex System x220 Compute Node Installation and Service Guide...
  • Page 433 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected. May also be shown as 806f070c2008ffff or 0x806f070c2008ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0126 User Response...
  • Page 434 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected. May also be shown as 806f070c200bffff or 0x806f070c200bffff Severity Error Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 435 CIM Information Prefix: PLAT ID: 0126 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the instructions under "User response."...
  • Page 436 • 806f070d-0401ffff : Rebuild in progress for Array in system [ComputerSystemElementName]. The RAID array in the specified system is being rebuilt. May also be shown as 806f070d0401ffff or 0x806f070d0401ffff Severity Info Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 437 Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0178 User Response Information only; no action is required. • 806f070d-0402ffff : Rebuild in progress for Array in system [ComputerSystemElementName]. The RAID array in the specified system is being rebuilt. May also be shown as 806f070d0402ffff or 0x806f070d0402ffff Severity Info...
  • Page 438 May also be shown as 806f070d0405ffff or 0x806f070d0405ffff Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0178 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 439 • 806f070d-0406ffff : Rebuild in progress for Array in system [ComputerSystemElementName]. The RAID array in the specified system is being rebuilt. May also be shown as 806f070d0406ffff or 0x806f070d0406ffff Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0178...
  • Page 440 Then, in the information center, open the topic for the UEFI diagnostic code and follow the instructions under "User response." • 806f0807-0302ffff : CPU 2 has been Disabled. This message is for the use case when an implementation has detected a Processor has been Disabled. Flex System x220 Compute Node Installation and Service Guide...
  • Page 441 May also be shown as 806f08070302ffff or 0x806f08070302ffff Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0061 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code"...
  • Page 442 May also be shown as 806f08132582ffff or 0x806f08132582ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Other Flex System x220 Compute Node Installation and Service Guide...
  • Page 443 SNMP Trap ID CIM Information Prefix: PLAT ID: 0240 User Response 1. Check http://www.ibm.com/supportportal/ for RETAIN tips or firmware updates that might correct the error. 2. Make sure that all I/O expansion adapters have correct and matching levels of device drivers and firmware.
  • Page 444 System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0142 User Response Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. Flex System x220 Compute Node Installation and Service Guide...
  • Page 445 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed. 3. Make sure that the room temperature is within operating specifications. 4. Make sure that the DIMM baffles are in place. 5.
  • Page 446 May also be shown as 806f090c20040104 or 0x806f090c20040104 Severity Warning Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0142 User Response Complete the following steps: Flex System x220 Compute Node Installation and Service Guide...
  • Page 447 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed. 3.
  • Page 448 May also be shown as 806f090c20070107 or 0x806f090c20070107 Severity Warning Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0142 User Response Complete the following steps: Flex System x220 Compute Node Installation and Service Guide...
  • Page 449 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed. 3.
  • Page 450 May also be shown as 806f090c200a010a or 0x806f090c200a010a Severity Warning Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0142 User Response Complete the following steps: Flex System x220 Compute Node Installation and Service Guide...
  • Page 451 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed. 3.
  • Page 452 3. Make sure that the room temperature is within operating specifications. • 806f0a07-0302ffff : CPU 2 is operating in a Degraded State. The processor is being throttled due to thermal or power conditions. Flex System x220 Compute Node Installation and Service Guide...
  • Page 453 May also be shown as 806f0a070302ffff or 0x806f0a070302ffff Severity Warning Serviceable Automatically notify support Alert Category Warning - CPU SNMP Trap ID CIM Information Prefix: PLAT ID: 0038 User Response Complete the following steps: 1. Check the CMM or FSM event log for any fan- or cooling-related issues or power-related issues.. 2.
  • Page 454 • 806f0a0c-20020102 : An Over-Temperature Condition has been detected on the memory device 2 in Group 1 on Subsystem System Memory. An overtemperature condition has been detected in the DIMM in DIMM connector 2. May also be shown as 806f0a0c20020102 or 0x806f0a0c20020102 Severity Flex System x220 Compute Node Installation and Service Guide...
  • Page 455 Error Serviceable Automatically notify support Alert Category Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0146 User Response Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
  • Page 456 5 in Group 1 on Subsystem System Memory. An overtemperature condition has been detected in the DIMM in DIMM connector 5. May also be shown as 806f0a0c20050105 or 0x806f0a0c20050105 Severity Error Flex System x220 Compute Node Installation and Service Guide...
  • Page 457 Serviceable Automatically notify support Alert Category Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0146 User Response Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
  • Page 458 8 in Group 1 on Subsystem System Memory. An overtemperature condition has been detected in the DIMM in DIMM connector 8. May also be shown as 806f0a0c20080108 or 0x806f0a0c20080108 Severity Error Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 459 Automatically notify support Alert Category Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0146 User Response Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
  • Page 460 11 in Group 1 on Subsystem System Memory. An overtemperature condition has been detected in the DIMM in DIMM connector 11. May also be shown as 806f0a0c200b010b or 0x806f0a0c200b010b Severity Error Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 461 Alert Category Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0146 User Response Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
  • Page 462 May also be shown as 806f0a130302ffff or 0x806f0a130302ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0244 User Response CPU 2 PECI : Flex System x220 Compute Node Installation and Service Guide...
  • Page 463 • 806f0a13-2401ffff : A Fatal Bus Error has occurred on bus SMBus. A fatal bus error has been detected on the System Management Bus. May also be shown as 806f0a132401ffff or 0x806f0a132401ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information...
  • Page 464 A fatal bus error has been detected in the I/O expansion adapter in PCIe adapter slot 1 in the PCI expansion unit. May also be shown as 806f0a133101ffff or 0x806f0a133101ffff Severity Error Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 465 CIM Information Prefix: PLAT ID: 0244 User Response This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the instructions under "User response."...
  • Page 466 81010202-0701ffff : Sensor [NumericSensorElementName] has detected that a voltage is no longer going low. A previously low voltage has returned to above its specified threshold (sensor Planar 12V, Planar 3.3V, or Planar 5V). May also be shown as 810102020701ffff or 0x810102020701ffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 467 Severity Info Serviceable Automatically notify support Alert Category Critical - Voltage SNMP Trap ID CIM Information Prefix: PLAT ID: 0481 User Response Information only; no action is required. • 81010202-2801ffff : Sensor [NumericSensorElementName] has detected that the battery voltage is no longer low.
  • Page 468 • 81010901-3701ffff : Sensor Inlet Temp has detected that the inlet temperature is no longer high. The previously high inlet temperature has returned to below its specified threshold. May also be shown as 810109013701ffff or 0x810109013701ffff Severity Info Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 469 Automatically notify support Alert Category Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0495 User Response Information only; no action is required. • 81010901-3702ffff : Numeric sensor PEN Inlet Temp going high (upper critical) has deasserted. The previously high inlet temperature has returned to below its specified threshold. May also be shown as 810109013702ffff or 0x810109013702ffff Severity Info...
  • Page 470 81010b01-3702ffff : Numeric sensor PEN Inlet Temp going high (upper non-recoverable) has deasserted. The previously high inlet temperature has returned to below its specified threshold. May also be shown as 81010b013702ffff or 0x81010b013702ffff Severity Info Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 471 Alert Category Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0499 User Response Information only; no action is required. • 81030006-2101ffff : Sensor Sig Verify Fail has asserted. Signature verification of one of the Firmware Volumes or Capsules in UEFI BIOS failed. May also be shown as 810300062101ffff or 0x810300062101ffff Severity Info...
  • Page 472 The previously high temperature of microprocessor 2 has returned to below its specified threshold. May also be shown as 8107010103020100 or 0x8107010103020100 Severity Info Serviceable Automatically notify support Alert Category Warning - Temperature SNMP Trap ID CIM Information Flex System x220 Compute Node Installation and Service Guide...
  • Page 473 Prefix: PLAT ID: 0521 User Response Information only; no action is required. • 81070101-2c01ffff : Sensor Mezz Exp 1 temp has deassserted the transition from normal to non-critical state. The temperature of the I/O expansion adapter in I/O expansion connector 1 is no longer in a non-critical state.
  • Page 474 The temperature of the PEN Messanne Expansion adapter in I/O expansion connector 4 is no longer in a non-critical state. May also be shown as 810701012c04ffff or 0x810701012c04ffff Severity Info Serviceable Automatically notify support Alert Category Warning - Temperature SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 475 CIM Information Prefix: PLAT ID: 0521 User Response Information only; no action is required. • 81070101-3101ffff : Sensor PCIE 1 Overtemp has deasserted the transition from normal to non-critical state. The temperature of the PCI expansion unit PCIe Card1 no longer in a non-critical state. May also be shown as 810701013101ffff or 0x810701013101ffff Severity Info...
  • Page 476 The temperature of the PCI expansion unit PCIe Card4 no longer in a non-critical state. May also be shown as 810701013104ffff or 0x810701013104ffff Severity Info Serviceable Automatically notify support Alert Category Warning - Temperature SNMP Trap ID CIM Information Flex System x220 Compute Node Installation and Service Guide...
  • Page 477 Prefix: PLAT ID: 0521 User Response Information only; no action is required. • 81070101-3702ffff : Sensor PEN Inlet Over T has deasserted the transition from normal to non-critical state. The PCIe Expansion Node Inlet temperature has returned to its specified threshold. May also be shown as 810701013702ffff or 0x810701013702ffff Severity Info...
  • Page 478 The temperature of the PCI expansion unit PCIe Card2 no longer in a critical state. May also be shown as 810702013102ffff or 0x810702013102ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0523 User Response Flex System x220 Compute Node Installation and Service Guide...
  • Page 479 Information only; no action is required. • 81070201-3103ffff : Sensor PCIE 3 Overtemp has transitioned to a less severe state from critical. The temperature of the PCI expansion unit PCIe Card3 no longer in a critical state. May also be shown as 810702013103ffff or 0x810702013103ffff Severity Info Serviceable...
  • Page 480 SNMP Trap ID CIM Information Prefix: PLAT ID: 0523 User Response Information only; no action is required. • 8107020f-2582ffff : Sensor No I/O Resources has transitioned to a less severe state from critical. Flex System x220 Compute Node Installation and Service Guide...
  • Page 481 This message is for the use case when an implementation has detected a Sensor transition to less severe from critical. May also be shown as 8107020f2582ffff or 0x8107020f2582ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0523 User Response...
  • Page 482 • 81070217-0b82ffff : Sensor PEN LPR Empty has transitioned to a less severe state from critical. This message is for the use case when an implementation has detected a Sensor transition to less severe from critical. May also be shown as 810702170b82ffff or 0x810702170b82ffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 483 Severity Info Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0523 User Response Information only; no user action required. • 81070217-2c01ffff : Sensor Mezz Exp 1 Fault has transitioned to a less severe state from critical. A fault is no longer detected in the I/O expansion adapter in I/O expansion connector 1.
  • Page 484 • 81070217-2c04ffff : Sensor PEN MExp 4 Fault has transitioned to a less severe state from critical. A fault is no longer detected in the PEN Mezzanine Expansion adapter in I/O expansion connector 4. May also be shown as 810702172c04ffff or 0x810702172c04ffff Severity Info Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 485 Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0523 User Response Information only; no action is required. • 81070217-3101ffff : Sensor PEN Slot1 Empty has transitioned to a less severe state from critical. PCIe adapter slot 1 in the PCI expansion unit is no longer empty.
  • Page 486 • 81070217-3104ffff : Sensor PEN Slot4 has transitioned to a less severe state from critical. PCIe adapter slot 4 in the PCI expansion unit is no longer empty. May also be shown as 810702173104ffff or 0x810702173104ffff Severity Info Serviceable Automatically notify support Alert Category Flex System x220 Compute Node Installation and Service Guide...
  • Page 487 Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0523 User Response Information only; no action is required. • 81070219-0701ffff : Sensor Sys Board Fault has transitioned to a less severe state from critical. This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.
  • Page 488 The previously high temperature of microprocessor 1 has returned to below its specified threshold. May also be shown as 8107030103010100 or 0x8107030103010100 Severity Info Serviceable Automatically notify support Alert Category Critical - Temperature SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 489 CIM Information Prefix: PLAT ID: 0525 User Response Information only; no action is required. • 81070301-03020100 : Sensor [SensorElementName] has gone from Nonrecoverable state to a less severe state. The previously high temperature of microprocessor 2 has returned to below its specified threshold. May also be shown as 8107030103020100 or 0x8107030103020100 Severity Info...
  • Page 490 The previously high temperature of the PEN Mezzanine Expansion adapter in I/O expansion connector 3 has returned to below its specified threshold. May also be shown as 810703012c03ffff or 0x810703012c03ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Temperature SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 491 CIM Information Prefix: PLAT ID: 0525 User Response Information only; no action is required. • 81070301-2c04ffff : Sensor PEN MExp 4 Temp has deasserted the transition to non-recoverable from a less severe state. The previously high temperature of the PEN Mezzanine Expansion adapter in I/O expansion connector 4 has returned to below its specified threshold.
  • Page 492 This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable from less severe has deasserted. May also be shown as 810703013103ffff or 0x810703013103ffff Severity Info Serviceable Automatically notify support Alert Category Flex System x220 Compute Node Installation and Service Guide...
  • Page 493 Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0525 User Response Information only; no action is required. • 81070301-3104ffff : Sensor PCIE 4 Overtemp has deasserted the transition to non-recoverable from a less severe state. This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable from less severe has deasserted.
  • Page 494 The previously high Mezzanine Expansion card temperature has returned below its specified threshold. May also be shown as 810706012c02ffff or 0x810706012c02ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Temperature Flex System x220 Compute Node Installation and Service Guide...
  • Page 495 SNMP Trap ID CIM Information Prefix: PLAT ID: 0531 User Response Information only; no action is required. • 81070601-2c03ffff : Sensor PEN MExp 3 temp has deasserted the transition to non-recoverable. The previously high PEN Mezzanine Expansion card temperature has returned below its specified threshold.
  • Page 496 81080017-0f01ffff : Device SAS BP has been added. The SAS backplane has been installed. May also be shown as 810800170f01ffff or 0x810800170f01ffff Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Flex System x220 Compute Node Installation and Service Guide...
  • Page 497 Prefix: PLAT ID: 0536 User Response Information only; no action is required. • 81090112-2101ffff : Device [LogicalDeviceElementName] has been disabled. An IPMI or SNMP Account has been disabled. May also be shown as 810901122101ffff or 0x810901122101ffff Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID...
  • Page 498 May also be shown as 810b050c2581ffff or 0x810b050c2581ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0811 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 499 • 816f0007-0301ffff : CPU 1 has Recovered from IERR. This message is for the use case when an implementation has detected a Processor Recovered - IERR Condition. May also be shown as 816f00070301ffff or 0x816f00070301ffff Severity Info Serviceable Automatically notify support Alert Category Critical - CPU SNMP Trap ID...
  • Page 500 SNMP Trap ID CIM Information Prefix: PLAT ID: 0107 User Response Information only; no action is required. • 816f000d-0400ffff : The Drive Drive 0 has been removed from unit Drive 0. Flex System x220 Compute Node Installation and Service Guide...
  • Page 501 Hard disk drive 0 is no longer detected. If there is no drive in the drive bay, a filler is required. May also be shown as 816f000d0400ffff or 0x816f000d0400ffff Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0163...
  • Page 502 Hard disk drive 3 is no longer detected. If there is no drive in the drive bay, a filler is required. May also be shown as 816f000d0403ffff or 0x816f000d0403ffff Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 503 CIM Information Prefix: PLAT ID: 0163 User Response Complete the following steps until the problem is solved: 1. If drive was intentionally removed, make sure that there is a filler in the drive bay. 2. Make sure that the drive is correctly seated. 3.
  • Page 504 • 816f000d-0407ffff : The Drive Drive 7 has been removed from unit Drive 7. Hard disk drive 7 is no longer detected. If there is no drive in the drive bay, a filler is required. May also be shown as 816f000d0407ffff or 0x816f000d0407ffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 505 Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0163 User Response Complete the following steps until the problem is solved: 1. If drive was intentionally removed, make sure that there is a filler in the drive bay. 2.
  • Page 506 Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0331 User Response Information only; no action is required. • 816f0021-2582ffff : Fault condition removed on slot [PhysicalConnectorElementName] on system [ComputerSystemElementName]. Flex System x220 Compute Node Installation and Service Guide...
  • Page 507 This message is for the use case when an implementation has detected a Fault condition in a slot has been removed. All PCI Error. One of PCI Error. May also be shown as 816f00212582ffff or 0x816f00212582ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID...
  • Page 508 May also be shown as 816f010c2002ffff or 0x816f010c2002ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0139 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 509 • 816f010c-2003ffff : Uncorrectable error recovery detected for DIMM 3 on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected a Memory uncorrectable error recovery. May also be shown as 816f010c2003ffff or 0x816f010c2003ffff Severity Info Serviceable Automatically notify support Alert Category...
  • Page 510 May also be shown as 816f010c2006ffff or 0x816f010c2006ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0139 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 511 • 816f010c-2007ffff : Uncorrectable error recovery detected for DIMM 7 on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected a Memory uncorrectable error recovery. May also be shown as 816f010c2007ffff or 0x816f010c2007ffff Severity Info Serviceable Automatically notify support Alert Category...
  • Page 512 May also be shown as 816f010c200affff or 0x816f010c200affff Severity Info Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0139 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 513 • 816f010c-200bffff : Uncorrectable error recovery detected for DIMM 11 on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected a Memory uncorrectable error recovery. May also be shown as 816f010c200bffff or 0x816f010c200bffff Severity Info Serviceable Automatically notify support Alert Category...
  • Page 514 May also be shown as 816f010d0400ffff or 0x816f010d0400ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Hard Disk drive SNMP Trap ID CIM Information Prefix: PLAT ID: 0167 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 515 • 816f010d-0401ffff : The Drive Drive 1 has been enabled. The previously disabled hard disk drive 1 has been enabled. May also be shown as 816f010d0401ffff or 0x816f010d0401ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Hard Disk drive SNMP Trap ID CIM Information Prefix: PLAT ID: 0167...
  • Page 516 Information only; no action is required. • 816f010d-0405ffff : The Drive Drive 5 has been enabled. The previously disabled hard disk drive 5 has been enabled. May also be shown as 816f010d0405ffff or 0x816f010d0405ffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 517 Severity Info Serviceable Automatically notify support Alert Category Critical - Hard Disk drive SNMP Trap ID CIM Information Prefix: PLAT ID: 0167 User Response Information only; no action is required. • 816f010d-0406ffff : The Drive Drive 6 has been enabled. The previously disabled hard disk drive 6 has been enabled.
  • Page 518 This message is for the use case when an implemenation has detected that a system has recovered from a Bus Timeout. May also be shown as 816f01130301ffff or 0x816f01130301ffff Severity Info Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 519 Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0225 User Response CPU 1 PECI : • 816f0113-0302ffff : Bus [SensorElementName] has recovered from a bus timeout. This message is for the use case when an implemenation has detected that a system has recovered from a Bus Timeout.
  • Page 520 This message is for the use case when an implementation has detected a Processor Recovered - FRB1/BIST condition. May also be shown as 816f02070301ffff or 0x816f02070301ffff Severity Info Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 521 Alert Category Critical - CPU SNMP Trap ID CIM Information Prefix: PLAT ID: 0045 User Response Information only; no action is required. • 816f0207-0302ffff : CPU 2 has Recovered from FRB1/BIST condition. This message is for the use case when an implementation has detected a Processor Recovered - FRB1/BIST condition.
  • Page 522 [ComputerSystemElementName]. Failure of hard disk drive 1 is no longer predicted. May also be shown as 816f020d0401ffff or 0x816f020d0401ffff Severity Info Serviceable Automatically notify support Alert Category System - Predicted Failure Flex System x220 Compute Node Installation and Service Guide...
  • Page 523 SNMP Trap ID CIM Information Prefix: PLAT ID: 0169 User Response Information only; no action is required. • 816f020d-0402ffff : Failure no longer Predicted on drive Drive 2 for array [ComputerSystemElementName]. Failure of hard disk drive 2 is no longer predicted. May also be shown as 816f020d0402ffff or 0x816f020d0402ffff Severity Info...
  • Page 524 Failure of hard disk drive 5 is no longer predicted. May also be shown as 816f020d0405ffff or 0x816f020d0405ffff Severity Info Serviceable Automatically notify support Alert Category System - Predicted Failure SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 525 CIM Information Prefix: PLAT ID: 0169 User Response Information only; no action is required. • 816f020d-0406ffff : Failure no longer Predicted on drive Drive 6 for array [ComputerSystemElementName]. Failure of hard disk drive 6 is no longer predicted. May also be shown as 816f020d0406ffff or 0x816f020d0406ffff Severity Info Serviceable...
  • Page 526 A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2002ffff or 0x816f030c2002ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0137 Flex System x220 Compute Node Installation and Service Guide...
  • Page 527 User Response Information only; no action is required. • 816f030c-2003ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2003ffff or 0x816f030c2003ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Memory...
  • Page 528 May also be shown as 816f030c2006ffff or 0x816f030c2006ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0137 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 529 • 816f030c-2007ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2007ffff or 0x816f030c2007ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0137...
  • Page 530 May also be shown as 816f030c200affff or 0x816f030c200affff Severity Info Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0137 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 531 • 816f030c-200bffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c200bffff or 0x816f030c200bffff Severity Info Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0137...
  • Page 532 Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0230 User Response Information only; no action is required. • 816f040c-2001ffff : DIMM 1 Enabled on Subsystem [MemoryElementName]. Flex System x220 Compute Node Installation and Service Guide...
  • Page 533 This message is for the use case when an implementation has detected that Memory has been Enabled. May also be shown as 816f040c2001ffff or 0x816f040c2001ffff Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0130 User Response Information only;...
  • Page 534 • 816f040c-2005ffff : DIMM 5 Enabled on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected that Memory has been Enabled. May also be shown as 816f040c2005ffff or 0x816f040c2005ffff Severity Info Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 535 Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0130 User Response Information only; no action is required. • 816f040c-2006ffff : DIMM 6 Enabled on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected that Memory has been Enabled. May also be shown as 816f040c2006ffff or 0x816f040c2006ffff Severity Info...
  • Page 536 This message is for the use case when an implementation has detected that Memory has been Enabled. May also be shown as 816f040c2009ffff or 0x816f040c2009ffff Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0130 User Response Flex System x220 Compute Node Installation and Service Guide...
  • Page 537 Information only; no action is required. • 816f040c-200affff : DIMM 10 Enabled on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected that Memory has been Enabled. May also be shown as 816f040c200affff or 0x816f040c200affff Severity Info Serviceable...
  • Page 538 • 816f0413-2582ffff : A PCI PERR recovery has occurred on system This message is for the use case when an implementation has detected a PCI PERR recovered. PCIs. May also be shown as 816f04132582ffff or 0x816f04132582ffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 539 Severity Info Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0233 User Response Information only; no action is required. • 816f0413-2c03ffff : A PCI PERR recovery has occurred on system [ComputerSystemElementName]. A PCI parity error is no longer detected in the I/O expansion adapter in PCIe adapter slot 3 in the PCI expansion unit.
  • Page 540 A PCI parity error is no longer detected in the I/O expansion adapter in PCIe adapter slot 2 in the PCI expansion unit. May also be shown as 816f04133102ffff or 0x816f04133102ffff Severity Flex System x220 Compute Node Installation and Service Guide...
  • Page 541 Info Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0233 User Response Information only; no action is required. • 816f0413-3103ffff : A PCI PERR recovery has occurred on system [ComputerSystemElementName]. A PCI parity error is no longer detected in the I/O expansion adapter in PCIe adapter slot 3 in the PCI expansion unit.
  • Page 542 • 816f0507-0302ffff : CPU 2 has Recovered from a Configuration Mismatch. This message is for the use case when an implementation has Recovered from a Processor Configuration Mismatch. May also be shown as 816f05070302ffff or 0x816f05070302ffff Severity Info Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 543 Automatically notify support Alert Category Critical - CPU SNMP Trap ID CIM Information Prefix: PLAT ID: 0063 User Response Information only; no action is required. • 816f0507-2584ffff : [ProcessorElementName] has Recovered from a Configuration Mismatch. This message is for the use case when an implementation has Recovered from a Processor Configuration Mismatch.
  • Page 544 [MemoryElementName]. This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed. May also be shown as 816f050c2003ffff or 0x816f050c2003ffff Severity Info Flex System x220 Compute Node Installation and Service Guide...
  • Page 545 Serviceable Automatically notify support Alert Category Warning - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0145 User Response Information only; no action is required. • 816f050c-2004ffff : Memory Logging Limit Removed for DIMM 4 on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.
  • Page 546 816f050c-2007ffff : Memory Logging Limit Removed for DIMM 7 on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed. May also be shown as 816f050c2007ffff or 0x816f050c2007ffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 547 Severity Info Serviceable Automatically notify support Alert Category Warning - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0145 User Response Information only; no action is required. • 816f050c-2008ffff : Memory Logging Limit Removed for DIMM 8 on Subsystem [MemoryElementName].
  • Page 548 816f050c-200bffff : Memory Logging Limit Removed for DIMM 11 on Subsystem [MemoryElementName]. This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed. May also be shown as 816f050c200bffff or 0x816f050c200bffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 549 Severity Info Serviceable Automatically notify support Alert Category Warning - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0145 User Response Information only; no action is required. • 816f050c-200cffff : Memory Logging Limit Removed for DIMM 12 on Subsystem [MemoryElementName].
  • Page 550 Information only; no action is required. • 816f050d-0401ffff : Critical Array [ComputerSystemElementName] has deasserted. The RAID array is no longer in a critical condition. May also be shown as 816f050d0401ffff or 0x816f050d0401ffff Severity Info Flex System x220 Compute Node Installation and Service Guide...
  • Page 551 Serviceable Automatically notify support Alert Category Critical - Hard Disk drive SNMP Trap ID CIM Information Prefix: PLAT ID: 0175 User Response Information only; no action is required. • 816f050d-0402ffff : Critical Array [ComputerSystemElementName] has deasserted. The RAID array is no longer in a critical condition. May also be shown as 816f050d0402ffff or 0x816f050d0402ffff Severity Info...
  • Page 552 • 816f050d-0405ffff : Critical Array [ComputerSystemElementName] has deasserted. The RAID array is no longer in a critical condition. May also be shown as 816f050d0405ffff or 0x816f050d0405ffff Severity Info Serviceable Automatically notify support Flex System x220 Compute Node Installation and Service Guide...
  • Page 553 Alert Category Critical - Hard Disk drive SNMP Trap ID CIM Information Prefix: PLAT ID: 0175 User Response Information only; no action is required. • 816f050d-0406ffff : Critical Array [ComputerSystemElementName] has deasserted. The RAID array is no longer in a critical condition. May also be shown as 816f050d0406ffff or 0x816f050d0406ffff Severity Info...
  • Page 554 A PCI system error is no longer detected in the I/O expansion adapter in PCIe adapter slot 3 in the PCI expansion unit. May also be shown as 816f05132c03ffff or 0x816f05132c03ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID Flex System x220 Compute Node Installation and Service Guide...
  • Page 555 CIM Information Prefix: PLAT ID: 0235 User Response Information only; no action is required. • 816f0513-2c04ffff : A PCI SERR on system [ComputerSystemElementName] has deasserted. A PCI system error is no longer detected in the I/O expansion adapter in PCIe adapter slot 4 in the PCI expansion unit.
  • Page 556 A PCI system error is no longer detected in the I/O expansion adapter in PCIe adapter slot 3 in the PCI expansion unit. May also be shown as 816f05133103ffff or 0x816f05133103ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0235 Flex System x220 Compute Node Installation and Service Guide...
  • Page 557 User Response Information only; no action is required. • 816f0513-3104ffff : A PCI SERR on system [ComputerSystemElementName] has deasserted. A PCI system error is no longer detected in the I/O expansion adapter in PCIe adapter slot 4 in the PCI expansion unit.
  • Page 558 May also be shown as 816f06072584ffff or 0x816f06072584ffff Severity Info Serviceable Automatically notify support Alert Category Critical - CPU SNMP Trap ID CIM Information Prefix: PLAT ID: 0817 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 559 • 816f060d-0400ffff : Array in system [ComputerSystemElementName] has been restored. The failed RAID array has been restored. May also be shown as 816f060d0400ffff or 0x816f060d0400ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Hard Disk drive SNMP Trap ID CIM Information Prefix: PLAT ID: 0177 User Response...
  • Page 560 Information only; no action is required. • 816f060d-0404ffff : Array in system [ComputerSystemElementName] has been restored. The failed RAID array has been restored. May also be shown as 816f060d0404ffff or 0x816f060d0404ffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 561 Severity Info Serviceable Automatically notify support Alert Category Critical - Hard Disk drive SNMP Trap ID CIM Information Prefix: PLAT ID: 0177 User Response Information only; no action is required. • 816f060d-0405ffff : Array in system [ComputerSystemElementName] has been restored. The failed RAID array has been restored.
  • Page 562 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted. May also be shown as 816f070c2001ffff or 0x816f070c2001ffff Severity Info Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 563 Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0127 User Response Information only; no action is required. • 816f070c-2002ffff : Configuration error for DIMM 2 on Subsystem [MemoryElementName]has deasserted. This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.
  • Page 564 816f070c-2005ffff : Configuration error for DIMM 5 on Subsystem [MemoryElementName]has deasserted. This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted. May also be shown as 816f070c2005ffff or 0x816f070c2005ffff Severity Flex System x220 Compute Node Installation and Service Guide...
  • Page 565 Info Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0127 User Response Information only; no action is required. • 816f070c-2006ffff : Configuration error for DIMM 6 on Subsystem [MemoryElementName]has deasserted. This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.
  • Page 566 816f070c-2009ffff : Configuration error for DIMM 9 on Subsystem [MemoryElementName]has deasserted. This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted. May also be shown as 816f070c2009ffff or 0x816f070c2009ffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 567 Severity Info Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0127 User Response Information only; no action is required. • 816f070c-200affff : Configuration error for DIMM 10 on Subsystem [MemoryElementName]has deasserted. This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.
  • Page 568 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted. All DIMMs. One of the DIMMs. May also be shown as 816f070c2581ffff or 0x816f070c2581ffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 569 Severity Info Serviceable Automatically notify support Alert Category Critical - Memory SNMP Trap ID CIM Information Prefix: PLAT ID: 0127 User Response Information only; no action is required. • 816f070d-0400ffff : Rebuild completed for Array in system [ComputerSystemElementName]. The rebuild of the RAID array is complete. May also be shown as 816f070d0400ffff or 0x816f070d0400ffff Severity Info...
  • Page 570 • 816f070d-0403ffff : Rebuild completed for Array in system [ComputerSystemElementName]. The rebuild of the RAID array is complete. May also be shown as 816f070d0403ffff or 0x816f070d0403ffff Severity Info Serviceable Automatically notify support Alert Category Flex System x220 Compute Node Installation and Service Guide...
  • Page 571 System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0179 User Response Information only; no action is required. • 816f070d-0404ffff : Rebuild completed for Array in system [ComputerSystemElementName]. The rebuild of the RAID array is complete. May also be shown as 816f070d0404ffff or 0x816f070d0404ffff Severity Info Serviceable...
  • Page 572 May also be shown as 816f070d0407ffff or 0x816f070d0407ffff Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0179 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 573 • 816f0807-0301ffff : CPU 1 has been Enabled. This message is for the use case when an implementation has detected a Processor has been Enabled. May also be shown as 816f08070301ffff or 0x816f08070301ffff Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information...
  • Page 574 816f090c-2001ffff : memory device 1 in Group 1 on Subsystem System Memory is no longer Throttled DIMM throttling in DIMM connector 1 has been turned off. May also be shown as 816f090c2001ffff or 0x816f090c2001ffff Flex System x220 Compute Node Installation and Service Guide...
  • Page 575 Severity Info Serviceable Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0143 User Response Information only; no action is required. • 816f090c-2002ffff : memory device 2 in Group 1 on Subsystem System Memory is no longer Throttled DIMM throttling in DIMM connector 2 has been turned off.
  • Page 576 816f090c-2005ffff : memory device 5 in Group 1 on Subsystem System Memory is no longer Throttled DIMM throttling in DIMM connector 5 has been turned off. May also be shown as 816f090c2005ffff or 0x816f090c2005ffff Severity Info Serviceable Flex System x220 Compute Node Installation and Service Guide...
  • Page 577 Automatically notify support Alert Category System - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0143 User Response Information only; no action is required. • 816f090c-2006ffff : memory device 6 in Group 1 on Subsystem System Memory is no longer Throttled DIMM throttling in DIMM connector 6 has been turned off.
  • Page 578 816f090c-2009ffff : memory device 9 in Group 1 on Subsystem System Memory is no longer Throttled DIMM throttling in DIMM connector 9 has been turned off. May also be shown as 816f090c2009ffff or 0x816f090c2009ffff Severity Info Serviceable Automatically notify support Alert Category System - Other Flex System x220 Compute Node Installation and Service Guide...
  • Page 579 SNMP Trap ID CIM Information Prefix: PLAT ID: 0143 User Response Information only; no action is required. • 816f090c-200affff : memory device 10 in Group 1 on Subsystem System Memory is no longer Throttled DIMM throttling in DIMM connector 10 has been turned off. May also be shown as 816f090c200affff or 0x816f090c200affff Severity Info...
  • Page 580 Microprocessor 1 throttling has been turned off. May also be shown as 816f0a070301ffff or 0x816f0a070301ffff Severity Info Serviceable Automatically notify support Alert Category Warning - CPU SNMP Trap ID CIM Information Prefix: PLAT ID: 0039 User Response Flex System x220 Compute Node Installation and Service Guide...
  • Page 581 Information only; no action is required. • 816f0a07-0302ffff : The Processor CPU 2 is no longer operating in a Degraded State. Microprocessor 2 throttling has been turned off. May also be shown as 816f0a070302ffff or 0x816f0a070302ffff Severity Info Serviceable Automatically notify support Alert Category Warning - CPU SNMP Trap ID...
  • Page 582 May also be shown as 816f0a0c2002ffff or 0x816f0a0c2002ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0147 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 583 • 816f0a0c-2003ffff : An Over-Temperature Condition has been removed on the memory device 3 in Group 1 on Subsystem System Memory. The DIMM in DIMM connector 3 is no longer in an overtemperature condition. May also be shown as 816f0a0c2003ffff or 0x816f0a0c2003ffff Severity Info Serviceable...
  • Page 584 May also be shown as 816f0a0c2006ffff or 0x816f0a0c2006ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0147 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 585 • 816f0a0c-2007ffff : An Over-Temperature Condition has been removed on the memory device 7 in Group 1 on Subsystem System Memory. The DIMM in DIMM connector 7 is no longer in an overtemperature condition. May also be shown as 816f0a0c2007ffff or 0x816f0a0c2007ffff Severity Info Serviceable...
  • Page 586 May also be shown as 816f0a0c200affff or 0x816f0a0c200affff Severity Info Serviceable Automatically notify support Alert Category Critical - Temperature SNMP Trap ID CIM Information Prefix: PLAT ID: 0147 User Response Information only; no action is required. Flex System x220 Compute Node Installation and Service Guide...
  • Page 587 • 816f0a0c-200bffff : An Over-Temperature Condition has been removed on the memory device 11 in Group 1 on Subsystem System Memory. The DIMM in DIMM connector 11 is no longer in an overtemperature condition. May also be shown as 816f0a0c200bffff or 0x816f0a0c200bffff Severity Info Serviceable...
  • Page 588 Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0245 User Response CPU 2 PECI : • 816f0a13-2401ffff : Bus [SensorElementName] has recovered from a Fatal Bus Error. Flex System x220 Compute Node Installation and Service Guide...
  • Page 589 This message is for the use case when an implementation has detected that a system has recovered from a Bus Fatal Error. SMBus. May also be shown as 816f0a132401ffff or 0x816f0a132401ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0245...
  • Page 590 Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0245 User Response Information only; no action is required. • 816f0a13-3102ffff : Bus PEN Slot2 has recovered from a Fatal Bus Error. Flex System x220 Compute Node Installation and Service Guide...
  • Page 591 A fatal bus error is no longer detected in the I/O expansion adapter in PCIe adapter slot 2 in the PCI expansion unit. May also be shown as 816f0a133102ffff or 0x816f0a133102ffff Severity Info Serviceable Automatically notify support Alert Category Critical - Other SNMP Trap ID CIM Information Prefix: PLAT ID: 0245...
  • Page 592: Uefi Diagnostic Codes

    It might also be a condition that requires additional monitoring or maintenance. • Error: The event is a failure or critical condition that impairs service or an expected function. User response The actions that you should perform to solve the event. Flex System x220 Compute Node Installation and Service Guide...
  • Page 593 Perform the steps listed in this section in the order shown until the problem is solved. After you perform all of the actions that are described in this field, if you cannot solve the problem, contact Support. Finding the UEFI diagnostic code This topic provides information about finding the UEFI diagnostic code.
  • Page 594 “Removing a microprocessor and heat sink” on page 675 – “Installing a microprocessor and heat sink” on page 678 – “Removing the system-board assembly” on page 683 – “Installing the system-board assembly” on page 684 Flex System x220 Compute Node Installation and Service Guide...
  • Page 595 • I.18007 [I.18007] A power segment mismatch has been detected for one or more processor packages. Explanation: Processors have mismatched Power Segments Severity Info User Response Complete the following steps: 1. Processors installed do not have the same power requirements 2.
  • Page 596 Explanation: Processors have one or more cache levels with mismatched size Severity Info User Response Complete the following steps: 1. Verify that matching processors are installed in the correct processor sockets. Correct any mismatch found. Flex System x220 Compute Node Installation and Service Guide...
  • Page 597 2. Check the IBM support site for an applicable service bulletin or firmware update that applies to this processor error. 3. Replace the system board. Related links – “Removing a microprocessor and heat sink” on page 675 – “Installing a microprocessor and heat sink” on page 678 –...
  • Page 598 “Installing the system-board assembly” on page 684 • I.18010 [I.18010] A processor stepping mismatch has been detected for one or more processor packages. Explanation: Processors of the same model have mismatched Stepping ID Severity Info User Response Flex System x220 Compute Node Installation and Service Guide...
  • Page 599 Complete the following steps: 1. Verify that matching processors are installed in the correct processor sockets. 2. Check the IBM support site for an applicable service bulletin or firmware update that applies to this processor error. 3. Replace the system board. Related links –...
  • Page 600 Menu and choose Clear IMM System Event Log and Restart Server. Related links – “Using the Setup utility” on page 24 • I.3818001 [I.3818001] The firmware image capsule signature for the currently booted flash bank is invalid. Flex System x220 Compute Node Installation and Service Guide...
  • Page 601 Explanation: Current Bank CRTM Capsule Update Signature Invalid Severity Info User Response Complete the following steps: 1. Reboot the system. Will come up on backup UEFI image. Update the primary UEFI image. 2. If error does not persist no additional recovery action is required. 3.
  • Page 602 User Response Complete the following steps: Information only; no action is required. • I.580A4 [I.580A4] Memory population change detected. Explanation: DIMM Population Change Detected Severity Info User Response Complete the following steps: Flex System x220 Compute Node Installation and Service Guide...
  • Page 603 Check system event log for uncorrected DIMM failures and replace those DIMMs. Related links – “Removing a DIMM” on page 652 – “Installing a DIMM” on page 654 • I.580A5 [I.580A5] Mirror Fail-over complete. DIMM number % has failed over to to the mirrored copy.
  • Page 604 Complete the following steps: 1. If this compute node and/or any attached cables were recently installed, moved, serviced or upgraded: a. Reseat the adapter and any attached cables. b. Reload the device driver. Flex System x220 Compute Node Installation and Service Guide...
  • Page 605 c. If device is not recognized, reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility. 2.
  • Page 606 Error User Response Complete the following steps: 1. Check the IBM support site for an applicable service bulletin or firmware update that applies to this error. 2. Update the UEFI image. Flex System x220 Compute Node Installation and Service Guide...
  • Page 607 3. Replace the system board. Related links – “Updating firmware and device drivers” on page 21 – “Removing the system-board assembly” on page 683 – “Installing the system-board assembly” on page 684 • S.3058004 [S.3058004] A Three Strike boot failure has occurred. The system has booted with default UEFI settings.
  • Page 608 “Updating firmware and device drivers” on page 21 • S.3818004 [S.3818004] The CRTM flash driver could not successfully flash the staging area. A failure occurred. Explanation: CRTM Update Failed Severity Error Flex System x220 Compute Node Installation and Service Guide...
  • Page 609 User Response Complete the following steps: 1. Continue booting the system. If the system does not reset, manually reset the system. 2. If the error is not reported on the subsequent boot, no additional recovery action is required. 3. If the error persists, continue booting system and update the UEFI image. 4.
  • Page 610 “Removing a microprocessor and heat sink” on page 675 – “Installing a microprocessor and heat sink” on page 678 • S.51009 [S.51009] No system memory has been detected. Explanation: No Memory Detected Flex System x220 Compute Node Installation and Service Guide...
  • Page 611 Severity Error User Response Complete the following steps: 1. If any memory errors are logged other than this one, take actions indicated for those codes first. 2. If no other memory diagnostic codes appear in the logs, verify that all DIMM connectors are enabled using the Setup utility or the Advanced Settings Utility (ASU).
  • Page 612 1. Check the IBM support site for an applicable service bulletin or firmware update that applies to this error. 2. Inspect the processor socket for foreign debris or damage. If debris is found, remove the debris. Flex System x220 Compute Node Installation and Service Guide...
  • Page 613 3. If error recurs, or socket damage is found, replace the system board. Related links – “Removing a microprocessor and heat sink” on page 675 – “Installing a microprocessor and heat sink” on page 678 – “Removing the system-board assembly” on page 683 –...
  • Page 614 “Installing the system-board assembly” on page 684 • W.3058009 [W.3058009] DRIVER HEALTH PROTOCOL: Missing Configuraiton. Requires Change Settings From F1. Explanation: DRIVER HEALTH PROTOCOL: Missing Configuration. Requires Change Settings From F1 Flex System x220 Compute Node Installation and Service Guide...
  • Page 615 Severity Warning User Response Complete the following steps: 1. Go to the Setup Utility (System Settings -> Settings -> Driver Health Status List) and find a driver/controller reporting Configuration Required status. 2. Search for the driver menu from System Settings and change settings appropriately. 3.
  • Page 616 User Response Complete the following steps: 1. Reboot the system. 2. If problem persists, switch to the backup UEFI image or update the current UEFI image. 3. Replace the system board. Flex System x220 Compute Node Installation and Service Guide...
  • Page 617 Related links – “Updating firmware and device drivers” on page 21 – “Removing the system-board assembly” on page 683 – “Installing the system-board assembly” on page 684 • W.3808000 [W.3808000] An IMM communication failure has occurred. Explanation: IMM Communication Failure Severity Warning User Response...
  • Page 618 4. Replace the system board. Related links – “Updating firmware and device drivers” on page 21 – “Removing the system-board assembly” on page 683 – “Installing the system-board assembly” on page 684 Flex System x220 Compute Node Installation and Service Guide...
  • Page 619 • W.3868001 [W.3868001] BOFM: Reset loop avoided - Multiple resets not allowed. Explanation: BOFM: Reset loop avoided - Multiple resets not allowed Severity Warning User Response Complete the following steps: 1. Update all firmware (including adapter firmware) to the latest levels. 2.
  • Page 620 (Link to IBM support service bulletins) 7. If problem continues to re-occur on the same DIMM connector, inspect DIMM connector for foreign material and remove, if found. If connector is damaged, replace system board. Flex System x220 Compute Node Installation and Service Guide...
  • Page 621 8. Remove the affected processor and inspect the processor socket pins for damaged or mis-aligned pins. If damage is found or the processor is an upgrade part, replace the system board. 9. Replace affected processor. 10. Replace the system board. Related links –...
  • Page 622: Troubleshooting By Symptom

    1. Check the IMM event log and follow the suggested actions to resolve any event codes (see “IMM event log” on page 63). 2. Find the symptoms that you are experiencing in the troubleshooting tables in this section and follow the suggested actions to solve any problems. Flex System x220 Compute Node Installation and Service Guide...
  • Page 623: Compute Node Start Problems

    2. Check http://www.lenovo.com/ serverproven/ to validate that the compute node supports the embedded hypervisor device. 3. Use the Setup utility to make sure that the embedded hypervisor device (USB key) is in the startup sequence.
  • Page 624 The I/O module is powered on and the applicable ports are enabled on the I/O module. b. All cables between the I/O module and the network device (switch or router) are correctly connected and secure, and that the activity LEDs are lit on the applicable ports. Flex System x220 Compute Node Installation and Service Guide...
  • Page 625 Check the connectors on the chassis midplane to ensure there are no bent pins. See the "Flex System Enterprise Chassis Types 8721, 8724, and 8725: Installation and Service Guide" at http://pic.dhe.ibm.com/infocenter/flexsys/information/topic/com.lenovo.acc.8721.doc/product_ page.html. d. Remove the I/O module and install a working I/O module in the same I/O bay.
  • Page 626 2. Restore the CMM default settings by pressing the reset button on the CMM. Cannot log in to the I/O module Use the information in this section to troubleshoot the compute node when you cannot log in to the I/O module. Flex System x220 Compute Node Installation and Service Guide...
  • Page 627 If it is not the same IP address, configure the IMM network settings correctly or reset the IMM to automatically acquire a new IP address. 4. Check http://www.lenovo.com/support for any firmware updates that might apply to this problem. You can view the release notes for a firmware update to determine the issues that the update addresses.
  • Page 628 If it is not the same IP address, configure the IMM network settings correctly or reset the IMM to automatically acquire a new IP address. 8. Check http://www.lenovo.com/support for any firmware updates that might apply to this problem. You can view the release notes for a firmware update to determine the issues that the update addresses.
  • Page 629 7. Check http://www.lenovo.com/support for any service bulletins that are related to I/O-module connectivity. 8. If the problem remains, replace the I/O module, and go to http://www.lenovo.com/support to submit a service request. 9. (Trained service technician only) Complete the following steps: a.
  • Page 630 4. Make sure that the configuration settings in the node are correct and that the port is enabled. 5. Check http://www.lenovo.com/support for any firmware updates that might apply to this issue. You can view the release notes for a firmware update to determine the issues that are addressed by the update.
  • Page 631 4. Make sure that the IP configuration settings on the node are correct and that the port is enabled. 5. Check http://www.lenovo.com/support for any firmware updates that might apply to this issue. You can view the release notes for a firmware update to determine the issues that are addressed by the update.
  • Page 632 Perform a virtual reseat of the I/O module. d. Replace the I/O module. 6. Check http://www.lenovo.com/support for any service bulletins that are related to network connectivity. 7. Remove the management node and make sure that the connectors on the chassis midplane and the management node are not damaged.
  • Page 633 IMM network settings correctly. 6. Check http://www.lenovo.com/support for any firmware updates that might apply to this issue. You can view the release notes for a firmware update to determine the issues that are addressed by the update.
  • Page 634 CMM interface so that a new IP address can be acquired. 6. Check http://www.lenovo.com/support for any firmware updates that might apply to this issue. You can view the release notes for a firmware update to determine the issues that are addressed by the update.
  • Page 635 If a system-management processor does not have a valid IP address, complete the following steps: a. Restart the CMM. b. Check http://www.lenovo.com/support for any firmware or software updates that might apply to this issue. You can view the release notes for a firmware update to determine the issues that are addressed by the update.
  • Page 636: Hard Disk Drive Problems

    2. Make sure that the drive is correctly seated in the drive bay and that there is no physical damage to the drive connectors. 3. Run the DSA SAS Fixed Disk or SAS Attached Disk diagnostic tests (see “Lenovo Dynamic System Analysis” on page 65).
  • Page 637: Intermittent Connectivity Problems

    Make sure that the device is configured correctly for the port (see “Using the Setup utility” on page 24). c. Run DSA Preboot USB diagnostics (see “Lenovo Dynamic System Analysis” on page 65). Intermittent KVM problems Complete the following steps until the problem is solved.
  • Page 638: Memory Problems

    DIMM might have been manually disabled (see “Using the Setup utility” on page 24). 5. Run memory diagnostics (see “Lenovo Dynamic System Analysis” on page 65). 6. Remove DIMMs until the compute node is showing the correct amount of memory. Install one DIMM at a time until you can determine the DIMM that is not working properly.
  • Page 639: Optional Device And Replaceable Component Installation Problems

    If you are accessing the compute node from a remote location, complete the following steps: 1. Make sure that all applications are running (no applications are hung). 2. Attempt to log out of the compute node and log back in. 3.
  • Page 640: Performance Problems

    Complete the following steps until the problem is solved: 1. Check the event log and resolve any issues related to the device. 2. See http://www.lenovo.com/ serverproven/ to make sure that the adapter is supported. 3. Make sure that the adapter is installed in a correct slot.
  • Page 641 Chassis Management menu. For more information, see the the "Flex System Chassis Management Module: User's Guide" at http://pic.dhe.ibm.com/infocenter/flexsys/information/topic/com.lenovo.acc.cmm.doc/ cmm_user_ guide.html. All fields and options are described in the CMM web interface online help. 5. Make sure that the Flex System Manager management node has completed the discovery of the compute node.
  • Page 642: Software Problems

    Move the compute node to another node bay. c. Replace the system-board assembly (see “Removing the system-board assembly” on page 683 and “Installing the system-board assembly” on page 684). Flex System x220 Compute Node Installation and Service Guide...
  • Page 643: Collecting Service Data

    Flex System Manager management node. 4. Check http://www.lenovo.com/support for any firmware updates that might apply to this issue. You can view the release notes for a firmware update to determine the issues that are addressed by the update.
  • Page 644 Flex System x220 Compute Node Installation and Service Guide...
  • Page 645: Chapter 7. Installing, Removing, And Replacing Compute Node Components

    • Blue on a component indicates touch points, where you can grip the component to remove it from or install it in the compute node, open or close a latch, and so on. • For a list of supported optional devices for the compute node, see http://www.lenovo.com/ serverproven/. System reliability guidelines Use these guidelines to ensure that the compute node meets the cooling and system reliability requirements: •...
  • Page 646: Handling Static-Sensitive Devices

    For optimum performance, you must upgrade the operating system to support SMP. See Chapter 3 “Installing the operating system” on page 43 and your operating-system documentation for additional information. Flex System x220 Compute Node Installation and Service Guide...
  • Page 647: Removing A Compute Node From A Chassis

    Removing a compute node from a chassis Use this information to remove a compute node from a Flex System chassis. Before you remove a compute node, complete the following steps: 1. Read “Safety” on page iii and “Installation guidelines” on page 637. 2.
  • Page 648 If you are installing a compute node model without an integrated Ethernet controller, you must install a network interface adapter before you install the compute node in the chassis for management network communication. For a list of supported optional devices for the compute node, see http://www.lenovo.com/ serverproven/.
  • Page 649: Removing And Replacing Consumable And Structural Parts

    Use this information to remove and replace consumable and structural parts. Replacement of the consumable and structural parts that are described in this section is your responsibility. If Lenovo installs a consumable and structural part at your request, you will be charged for the installation. Removing the chassis bulkhead Use this information to remove the chassis bulkhead.
  • Page 650: Installing The Chassis Bulkhead

    Install the air baffles, if you removed them. After you install the chassis bulkhead, complete the following steps: 1. Install the cover onto the compute node (see “Installing the compute node cover” on page 644 for instructions). Flex System x220 Compute Node Installation and Service Guide...
  • Page 651: Removing The Compute Node Cover

    2. Install the compute node into the chassis (see “Installing a compute node in a chassis” on page 639 for instructions). Removing the compute node cover Use this information to remove the cover from a compute node. Before you remove the compute node cover, complete the following steps: 1.
  • Page 652: Installing The Compute Node Cover

    Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you. Step 2. Orient the cover so that the posts on the inside of the cover slide into the slots on the compute node. Flex System x220 Compute Node Installation and Service Guide...
  • Page 653: Removing The Front Handle

    Note: Before you close the cover, make sure that the air baffles and all components are installed and seated correctly and that you have not left loose tools or parts inside the compute node. Push point Release button Posts Slots Step 3.
  • Page 654: Installing The Front Handle

    To install the front handle, complete the following steps. Front handle Step 1. Orient the front handle so that the blue release latch is toward the middle of the compute node. Flex System x220 Compute Node Installation and Service Guide...
  • Page 655: Removing The Hard Disk Drive Cage

    Step 2. Align the hole in the handle with the hole on the compute node where the handle is installed. Step 3. Using a T15 Torx screwdriver, install the screw that secures the handle. Install the screw that you removed when you removed the handle. After you install the front handle, install the compute node into the chassis (see “Installing a compute node in a chassis”...
  • Page 656: Removing And Replacing Tier 1 Customer Replaceable Units (Crus)

    Removing and replacing Tier 1 customer replaceable units (CRUs) Use this information for removing and replacing Tier 1 CRUs. Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1 CRU at your request, you will be charged for the installation.
  • Page 657: Installing The Bezel

    If the compute node came with a RFID tag attached to the bezel, you must obtain and install a replacement RFID tag. • To obtain a RFID tag, see Chapter 5 “Parts listing, Types 2585 and 7906” on page 55 •...
  • Page 658: Removing The Cmos Battery

    If a cover is over the CMOS battery, remove the cover. Step 4. Pivot the CMOS battery toward the left of the compute node. Step 5. Lift the CMOS battery from the socket. Flex System x220 Compute Node Installation and Service Guide...
  • Page 659: Installing The Cmos Battery

    After you remove the CMOS battery, dispose of the CMOS battery as required by local ordinances or regulations. Installing the CMOS battery Use this information to install a CMOS battery. Before you install the CMOS battery, complete the following steps: 1.
  • Page 660: Removing A Dimm

    Start the Setup utility and select Save Settings (see “Using the Setup utility” on page 24 for more information) to save changes. To remove a DIMM, complete the following steps. Flex System x220 Compute Node Installation and Service Guide...
  • Page 661 Step 1. Remove the cover (see “Removing the compute node cover” on page 643). Step 2. Remove the air baffle installed over the DIMM connector. Left air baffle Right air baffle Step 3. Locate the DIMM connectors (see “System-board connectors” on page 17). Determine which DIMM you want to remove from the compute node.
  • Page 662: Installing A Dimm

    The compute node supports low-profile (LP) DDR3 DIMMs with error-correcting code (ECC) in 2 GB, 4 GB, 8 GB, and 16 GB capacities. The following illustration shows the system-board components, including the DIMM connectors. Flex System x220 Compute Node Installation and Service Guide...
  • Page 663 CMOS Microprocessor 2 I/O expansion 1 DIMMs battery Front Fabric (some models only) backplane Internal I/O expansion 2 ServeRAID controller I/O expansion 3 Light path Internal DIMMs diagnostic panel Microprocessor 1 The compute node has six memory channels with two dual inline memory module (DIMM) connectors each, for a total of 12 DIMM connectors.
  • Page 664 Remove the air baffle installed over the DIMM connector. Left air baffle Right air baffle Step 4. Locate the DIMM connectors (see “System-board connectors” on page 17). Determine which DIMM connector you want to install the DIMM in. Flex System x220 Compute Node Installation and Service Guide...
  • Page 665 Step 5. Touch the static-protective package that contains the DIMM to any unpainted metal surface on the Flex System chassis or any unpainted metal surface on any other grounded rack component in the rack in which you are installing the DIMM for at least 2 seconds; then, remove the DIMM from its package.
  • Page 666 DIMM connectors Installation order With one microprocessor With two microprocessors 5 and 6 5 and 6, 7 and 8 3 and 4 3 and 4 1 and 2 9 and 10 Flex System x220 Compute Node Installation and Service Guide...
  • Page 667: Removing A Fabric Connector

    Table 13. Rank-sparing mode DIMM installation sequence (continued) DIMM connectors Installation order With one microprocessor With two microprocessors 1 and 2 11 and 12 Mirrored-channel mode In mirrored-channel mode, the channels are paired, and both channels in a pair store the same data. For each microprocessor, DIMM channels 2 and 3 form one redundant pair, and channel 1 is unused.
  • Page 668: Installing A Fabric Connector

    3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you. 4. Obtain a #1 Phillips screwdriver. To install a fabric connector, complete the following steps. Flex System x220 Compute Node Installation and Service Guide...
  • Page 669: Removing The Hard Disk Drive Backplane

    Captive screws Fabric connector Step 1. Remove the cover (see “Removing the compute node cover” on page 643). Step 2. Locate the fabric connector (see “System-board layouts” on page 17). Step 3. Orient the fabric connector on the system board. Step 4.
  • Page 670: Installing The Hard Disk Drive Backplane

    Step 3. Slide the hard disk drive and hard disk drive bay filler into the bay until it is firmly seated in the connector. Flex System x220 Compute Node Installation and Service Guide...
  • Page 671: Removing A Hot-Swap Hard Disk Drive

    Step 4. Lock the hard disk drive into place by closing the release lever. After you install the hard disk drive backplane, complete the following steps: 1. Install the cover onto the compute node (see “Installing the compute node cover” on page 644 for instructions).
  • Page 672: Removing A Serveraid Controller

    2. If the compute node is installed in an Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 639 for instructions). 3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you. Flex System x220 Compute Node Installation and Service Guide...
  • Page 673: Installing A Serveraid Controller

    Note: If possible, backup or record your RAID configuration information before replacing the adapter. See the documentation for your RAID adapter for information and instructions. Documentation for ServeRAID adapters can be downloaded from the Lenovo Support Portal If you are installing a ServeRAID M5115 controller, go to http://pic.dhe.ibm.com/infocenter/ flexsys/information/topic/ com.ibm.acc.common.nav.doc/options.html for a link to the ServeRAID M5115...
  • Page 674: Removing An I/O Expansion Adapter

    3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you. To remove an I/O expansion adapter, complete the following steps. Flex System x220 Compute Node Installation and Service Guide...
  • Page 675: Installing An I/O Expansion Adapter

    Expansion nodes support a wide variety of industry-standard PCI Express, network, storage, and graphics adapters. For additional information, see "PCIe Expansion Node" at http://pic.dhe.ibm.com/infocenter/ flexsys/information/topic/ com.lenovo.acc.pme.doc/ product_page.html. To install an I/O expansion adapter, complete the following steps.
  • Page 676: Removing The Light Path Diagnostics Panel

    3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you. To remove the light path diagnostics panel, complete the following steps. Flex System x220 Compute Node Installation and Service Guide...
  • Page 677: Installing The Light Path Diagnostics Panel

    Light path Bracket diagnostics panel Connector Step 1. Remove the cover (see “Removing the compute node cover” on page 643). Step 2. Pull the light path diagnostics panel out of the bracket. Step 3. Disconnect the cable from the system board. Step 4.
  • Page 678: Removing The Rfid Tag

    Use this information to remove the RFID tag from the bezel. Before you remove the RFID tag, read “Safety” on page iii and “Installation guidelines” on page 637. To remove the RFID tag, complete the following steps. Flex System x220 Compute Node Installation and Service Guide...
  • Page 679: Installing The Rfid Tag

    Step 1. If the RFID tag is attached to the hinge, open the RFID tag. Step 2. Use pliers to carefully grip the hinge and gently pull and twist the base from the bezel. If you are instructed to return the RFID tag, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.
  • Page 680: Installing The Usb Flash Drive

    Remove the cover (see “Removing the compute node cover” on page 643). Step 2. Locate the USB connector on the system-board (see “System-board connectors” on page 17). Step 3. Push the USB flash drive into the connector. Flex System x220 Compute Node Installation and Service Guide...
  • Page 681: Removing And Replacing Tier 2 Customer Replaceable Units (Crus)

    Use this information for removing and replacing Tier 2 CRUs. You may install a Tier 2 CRU yourself or request Lenovo to install it, at no additional charge, under the type of warranty service that is designated for the compute node.
  • Page 682: Installing The Adapter-Retention Assembly

    The adapter-retention assembly consists of five separate parts. You can replace the parts that you choose and save the unused parts for future use. To install the adapter-retention assembly, complete the following steps. Flex System x220 Compute Node Installation and Service Guide...
  • Page 683: Removing A Microprocessor And Heat Sink

    Adapter-retention assembly Screws Step 1. Remove the cover (see “Removing the compute node cover” on page 643). Step 2. Remove the air baffles. Step 3. Carefully place the chassis on its side with the front handle side up. Step 4. Align the adapter-retention assembly on the system board.
  • Page 684 Use a screwdriver to loosen the screws on the heat sink, rotating each screw two full turns until each screw is loose. Gently pull the heat sink from the microprocessor. Flex System x220 Compute Node Installation and Service Guide...
  • Page 685 Attention: Do not use any tools or sharp objects to lift the release levers on the microprocessor socket. Doing so might result in permanent damage to the system board. Be extremely careful, the microprocessor socket contacts are very fragile. Step 4. Open the microprocessor socket release levers and retainer.
  • Page 686: Installing A Microprocessor And Heat Sink

    1. Read “Safety” on page iii and “Installation guidelines” on page 637. 2. If the compute node is installed in an Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 639 for instructions). Flex System x220 Compute Node Installation and Service Guide...
  • Page 687 3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you. The following notes describe the type of microprocessor that the compute node supports and other information that you must consider when you install a microprocessor: •...
  • Page 688 Release the sides of the cover and remove the cover from the installation tool. The microprocessor is preinstalled on the installation tool. Flex System x220 Compute Node Installation and Service Guide...
  • Page 689 Installation tool Microprocessor Cover Note: Do not touch the microprocessor contacts. Contaminants on the microprocessor contacts, such as oil from your skin, can cause connection failures between the contacts and the socket. Align the installation tool with the microprocessor socket. The installation tool rests flush on the socket only if it is properly aligned.
  • Page 690: Thermal Grease

    2. Install the compute node in an Flex System chassis (see “Installing a compute node in a chassis” on page 639 for instructions). Thermal grease Use this information to determine the guidelines for using thermal grease on a heat sink and microprocessor. Flex System x220 Compute Node Installation and Service Guide...
  • Page 691: Removing The System-Board Assembly

    The thermal grease must be replaced whenever the heat sink has been removed from the top of the microprocessor and is going to be reused or when debris is found in the grease. To replace damaged or contaminated thermal grease on the microprocessor and heat sink, complete the following steps: Step 1.
  • Page 692: Installing The System-Board Assembly

    If you are instructed to return the system-board assembly, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. Installing the system-board assembly Use this information to install the system-board assembly. Flex System x220 Compute Node Installation and Service Guide...
  • Page 693 Note: This procedure should be performed only by trained service technicians. Before you install the system-board assembly, complete the following steps: 1. Read “Safety” on page iii and “Installation guidelines” on page 637. 2. If the compute node is installed in an Flex System chassis, remove it (see “Removing a compute node from a chassis”...
  • Page 694 Universally Unique Identifier and DMI/SMBIOS data” on page 30). 6. Update the compute node with the latest firmware or restore the preexisting firmware (see “Updating firmware and device drivers” on page 21 for more information). Flex System x220 Compute Node Installation and Service Guide...
  • Page 695: Appendix A. Getting Help And Technical Assistance

    Before you call, make sure that you have taken these steps to try to solve the problem yourself. If you believe that you require warranty service for your Lenovo product, the service technicians will be able to assist you more efficiently if you prepare before you call.
  • Page 696: Using The Documentation

    • Secure upload with the system serial number: https://www.ecurep.ibm.com/ app/upload_hw Creating a personalized support web page You can create a personalized support web page by identifying Lenovo products that are of interest to you. To create a personalized support web page, go to http://www.ibm.com/support/ mynotifications. From this personalized page, you can subscribe to weekly email notifications about new technical documents, search for information and downloads, and access various administrative services.
  • Page 697: Hardware Service And Support

    IBM is Lenovo's preferred service provider for the System x, Flex System and NeXtScale System products. You can receive hardware service through your Lenovo reseller or from IBM. To locate a reseller authorized by Lenovo to provide warranty service, go to http://www.ibm.com/partnerworld and click Business Partner Locator.
  • Page 698 Flex System x220 Compute Node Installation and Service Guide...
  • Page 699: Appendix B. Notices

    Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead.
  • Page 700: Trademarks

    (TBW). A device that has exceeded this limit might fail to respond to system-generated commands or might be incapable of being written to. Lenovo is not responsible for replacement of a device that has exceeded its maximum guaranteed number of program/erase cycles, as documented in the Official Published Specifications for the device.
  • Page 701: Particulate Contamination

    If Lenovo determines that the levels of particulates or gases in your environment have caused damage to the device, Lenovo may condition provision of repair or replacement of devices or parts on implementation of appropriate remedial measures to mitigate such environmental contamination.
  • Page 702: Electronic Emission Notices

    Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Lenovo is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user's authority to operate the equipment.
  • Page 703: Germany Class A Statement

    Geräte der Klasse A. Dieses Gerät ist berechtigt, in Übereinstimmung mit dem Deutschen EMVG das EG-Konformitätszeichen - CE - zu führen. Verantwortlich für die Konformitätserklärung nach Paragraf 5 des EMVG ist die Lenovo (Deutschland) GmbH, Meitnerstr. 9, D-70563 Stuttgart. Informationen in Hinsicht EMVG Paragraf 4 Abs. (1) 4:Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A.
  • Page 704: Japanese Electromagnetic Compatibility Statements

    This is for any areas other than home. Russia Electromagnetic Interference (EMI) Class A statement People's Republic of China Class A electronic emission statement Taiwan Class A compliance statement Flex System x220 Compute Node Installation and Service Guide...
  • Page 705: Taiwan Bsmi Rohs Declaration

    Taiwan BSMI RoHS declaration Appendix B. Notices...
  • Page 706 Flex System x220 Compute Node Installation and Service Guide...
  • Page 707: Index

    LED devices and I/O ports, Setup utility China Class A electronic emission statement diagnostic tools Class A electronic emission notice dimensions, Flex System x220 Compute Node CMM cannot ping the CMM DIMM CMOS battery installing installing...
  • Page 708 World Wide Web location from World Wide Web removing sending diagnostic data fault LED sources of FCC Class A notice host server startup sequence, changing Flex System x220 Compute Node Installation and Service Guide...
  • Page 709 IP addresses, LAN over USB installing removing specifications memory problems Japanese electromagnetic compatibility statements memory, Setup utility jumpers, system board messages UEFI diagnostic codes microprocessor KCS address, IMM2 installing keyboard controller style address, IMM2 removing © Copyright Lenovo 2014, 2016...
  • Page 710 POST hardware and software event viewer software POST event log returning a device or component POST watchdog timer, Setup utility RFID Flex System x220 Compute Node Installation and Service Guide...