Electrical Instructions - Philips 200P7ES/00 Service Manual

20.1" lcd monitor
Hide thumbs Also See for 200P7ES/00:
Table of Contents

Advertisement

32
200P7 LCD
Go to cover page
Remark : Mode 35:/ 36 1600 * 1200 70 Hz and 75Hz only supported
by analog signal , DVI can' t support these mode
3.
AC, DC power board
3.1
Setup the AC I/P at 90VAC, and 18V panel loading 0.25A, the
voltage is 18V +/- 0.9V, inverter 18V loading 1.8A, the output
voltage is 18V +/- 0.9V, 5V loading 1.2A, the DC output voltage is
5V +/-0.25VDC,
4.
Display Adjustment
4.1
Access to factory mode (IIC) in auto-alignment system
The communication protocol switch to IIC .
4.2
Auto color adjustment (B)
Apply a 1280x1024/60Hz signal with Black ( 0mV) and
white ( 700 mV) pattern, set brightness control at 100%,
and contrast control at 50%.
Adjust the R. G. B offset, and gain to calibrate the color
smoothly and 64-gray level distinguishable.
Check all factory pre-setting modes.
4.3
Adjustment of WHITE-D (B)
Apply a 1280*1024 / 60Hz signal with white pattern, set brightness
control at 100%, and contrast control at 50%. Adjust the R, G, B
Sub-Gain, for the screen center, the 1931 CIE chromaticity (X, Y)
co-ordinates shall be;
x (center)
y (center)
Use Minolta CA-110 for colour coordinates and luminance check.
Luminance is > 200 Nits in the center of the screen when brightness
at 100% and
contrast set to 100%.
4.4
Adjustment of sRGB
Apply a 1280*1024 / 60Hz signal with white pattern, set brightness control at
100%, and contrast control at 50%. Adjust the R, G, B Sub-Gain, for the screen
center, the 1931 CIE chromaticity (X, Y) co-ordinates shall be;
x(center)
y(center)

Electrical instructions

9300°K
6500°K
0.283 ± 0.005
0.313 ± 0.005
0.297 ± 0.005
0.329 ± 0.005
sRGB
0.313 ± 0.005
0.329 ± 0.005

Advertisement

Table of Contents
loading