Siemens SISTORE AX4 Lite 1000/100 Configuration & Operation Manual page 46

Table of Contents

Advertisement

Configuration
46
Siemens AG
Fig. 40
Video Loss Actions screen
The DVR can be set to react to video blind differently for each camera. Each camera
can be associated with another camera, trigger an Alarm-Out connector, sound the
DVR's internal buzzer, notify a number of different devices, and/or move PTZ
cameras to preset positions.
3.
Highlight the box under the Record heading and press the
Î
A list of cameras appears.
You can associate as many cameras with that camera as you wish. If the DVR
detects video blind on the selected camera, it starts recording video from all the
associated cameras.
NOTE
The DVR supports both Black Blind and Whit Blind Detection.
NOTE
Video Blind might NOT be detected for a camera with very noisy image especially when set for low
sensitivity values.
4.
Highlight the box under the Alarm-Out heading and press the
5.
Select between Alarm Output and Beep (DVR's internal buzzer) that you would
like to activate and to sound whenever the DVR detects video loss on the
selected camera.
NOTE
For the Alarm-Out action, the alarm output and beep you select should be set to the Event mode in
the Alarm-Out setup screen (Schedule tab).
6.
Highlight the box under the Notify heading and press the
You can toggle the entire list On and Off by highlighting Notification and
pressing the
button. You can toggle the individual items On and Off by
highlighting that item and pressing the
7.
Highlight OK and press the
button.
button to accept your changes.
button.
button.
button.