Co: Output Signal Wordwise 0 / Outp_Sig Word 0; Co: Output Signal Wordwise 1 / Outp_Sig Word 1; Co: Output Signal Wordwise 2 / Outp_Sig Word 2 - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
Dependency:
Refer to: p8501
r8512

CO: Output signal wordwise 0 / Outp_sig word 0

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the signal interconnected via connector input p8502.
Dependency:
Refer to: p8502
r8513

CO: Output signal wordwise 1 / Outp_sig word 1

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the signal interconnected via connector input p8503.
Dependency:
Refer to: p8503
r8514

CO: Output signal wordwise 2 / Outp_sig word 2

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the signal interconnected via connector input p8504.
Dependency:
Refer to: p8504
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
From BI: p8501[0]
From BI: p8501[1]
From BI: p8501[2]
From BI: p8501[3]
From BI: p8501[4]
From BI: p8501[5]
From BI: p8501[6]
From BI: p8501[7]
From BI: p8501[8]
From BI: p8501[9]
From BI: p8501[10]
From BI: p8501[11]
From BI: p8501[12]
From BI: p8501[13]
From BI: p8501[14]
From BI: p8501[15]
From BI: p8501[16]
From BI: p8501[17]
From BI: p8501[18]
From BI: p8501[19]
From BI: p8501[20]
From BI: p8501[21]
1 signal
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Calculated: -
Dyn. index: -
Units group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Units group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Units group: -
Scaling: PERCENT
Max
- [%]
2 Parameters
2.2 List of parameters
0 signal
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Access level: 2
Func. diagram: 2195
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 2195
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 2195
Unit selection: -
Expert list: 1
Factory setting
- [%]
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
749

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents