Sound Power Level; Sound Pressure Level; Vibration Level - Toro 08703 Operator's Manual

Traction units
Hide thumbs Also See for 08703:
Table of Contents

Advertisement

or disconnecting from battery. Wear protective clothing
and use insulated tools.
Make sure all hydraulic line connectors are tight and all
hydraulic hoses and lines are in good condition before
applying pressure to the system.
Keep your body and hands away from pin hole leaks or
nozzles that eject hydraulic fluid under high pressure.
Use paper or cardboard, not your hands, to search for
leaks. Hydraulic fluid escaping under pressure can have
sufficient force to penetrate the skin and cause serious
injury. Seek immediate medical attention if fluid is
injected into skin.
Before disconnecting or performing any work on
the hydraulic system, all pressure in the system must
be relieved by stopping the engine and lowering the
attachments to the ground.
Check all fuel lines for tightness and wear on a regular
basis. Tighten or repair them as needed.
If the engine must be running to perform a maintenance
adjustment, keep hands, feet, clothing, and any parts of
the body away from the attachments and any moving
parts, especially the screen at the side of the engine. Keep
everyone away.
To ensure safety and accuracy, have an Authorized Toro
Distributor check the maximum engine speed with a
tachometer.
If major repairs are ever needed or if assistance is
desired, contact an Authorized Toro Distributor. Use
only Toro-approved attachments and replacement parts.
The warranty may be voided if used with unapproved
attachments.
Hauling
Use care when loading or unloading the machine into a
trailer or truck.
Use full width ramps for loading machine into trailer or
truck.
Tie the machine down securely using straps, chains, cable,
or ropes. Both front and rear straps should be directed
down and outward from the machine

Sound Power Level

This unit has a guaranteed sound power level of 97 dBA,
which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in ISO 11094.

Sound Pressure Level

This unit has a sound pressure level at the operator's ear of 83
dBA, which includes an Uncertainty Value (K) of 1 dBA.
Sound pressure level was determined according to the
procedures outlined in EN ISO 11201.

Vibration Level

Hand-Arm
Measured vibration level for right hand = .27 m/s
Measured vibration level for left hand = .29 m/s
Uncertainty Value (K) = 0.5 m/s
Measured values were determined according to the procedures
outlined in EN 1032.
Whole Body
Measured vibration level = 0.5 m/s
Uncertainty Value (K) = 0.5 m/s
Measured values were determined according to the procedures
outlined in EN 1032.