Adapter Plug (Modem Cable); Approvals, Certification; Operating Characteristics And Durability; Transport - Siemens SIMpad SL4 Technical Description

Hide thumbs Also See for SIMpad SL4:
Table of Contents

Advertisement

6.2.2
6.3
6.3.1
6.3.2
Siemens AG
ICM CP

Adapter plug (modem cable)

1
5
(male)
1
2
3
4
5
6
7
8
9
10
11
12

Approvals, certification

Operating characteristics and durability

The details in the table below are based on normal usage of the SIMpad SL4:
TFT display
Touch panel
Electrical safety
EMC
After 400 charge/discharge cycles, the Lithium ion battery suffers a capacity reduction
due to physical factors, down to a guaranteed residual capacity of not less than 50%.
The following components can be replaced by Service when a repair is carried out:
screen and touch panel (one unit)
battery
board

Transport

Transport class
Transport condition
Temperature range
Relative humidity
Test conditions
Lower temperature
6
9
CD
RXD
TXD
DTR
GND
DSR
RTS
CTS
Fig. 14 Wiring of the adapter plug
Max. 10,000 hours operating time
Max. 300,000 strokes with the pen or max. 2 million touches
with a finger
As per EN 60950
As per EN 55022 and EN 55024
ETS 300 019-1-2, Class 2.3 (except for temperature range!)
Device in its original packing, not in operation
-20 ° ... +60 °C (differs from ETS 300 019-1-2, Class 2.2)
+40 °C / 95 % rel. humidity, 96 hours
-20 °C, 72 hours
Technical Description
SIMpad SL4
Version V2.0
1
6
9
5
(male)
1
CD
2
TXD
3
RXD
4
DSR
5
GND
6
DTR
7
CTS
8
RTS
9
10
11
12
20.08.01, David Brunner
66/74