DAG 500 Internal blower
The blower box can be mounted in
such a way that the vent collar is
aligned to the left, the right, downwards
or towards the rear, as desired.
Connection plate when using the
DAG 1000 external blower
The blower or the connection plate can
also be mounted in the same position
on the rear of the appliance.
x = Distance to the rear of the cabinet
or wall. Must be a minimum of ½"
(13 mm).
Exhaust duct connection diameters
DA 6480, 6490 with internal blower
DAG 500:. . . . . . . . . . . . 6" C (150 mm)
DA 6480, 6490 with external blower
DAG 1000: . . . . . . . . . . 10" C (254 mm)
Appliance dimensions
21