SINGLE OVEN
SOVB53011***
SOVB53021***
SOVB53031***
TECHNICAL DATA
SOVB73031***
For cutout dimensions see following section titled:
Preparing location
DOUBLE OVEN
DOUBLE OVEN
DOVB53041***
HCW3485AES
DOVB53051***
DOVB73051***

INSTALLATION NOTES

DOVB53071***
1.
Do not slide oven across floor. Damage to floor covering
or floor could result.
DOVB73071***
2.
The oven support surface must be a minimum 3/4" (2cm)
thick plywood platform.
***Digits identifying oven color and version
For single ovens, it must support 202 pounds.
For double ovens, it must support 379 pounds. The
platform must be solid, level and flush with the bottom of
the cabinet cut out.
3.
Use extreme caution when moving or installing the oven.
It is very heavy.
DO NOT LIFT THE OVEN BY THE DOOR HANDLE,
remove the door for easier handling and installing.
See REMOVING THE DOOR in the maintenance section
of the Use Care Manual.
4.
Be very careful when moving or installing the oven to
avoid damage to the oven frame or damage to the cabinets.
5.
Be sure to level the oven. An oven that is not level may
provide poor or inconsistent baking results.
6.
Be careful when placing oven. DO NOT pinch the conduit
between the oven back.
Ltr.
A
Cutout Width
B
Cutout Depth
C
Cutout Height
D
Floor Bottom of Cutout
E
Minimum Spacing
4
UPPER CAVITY
LOWER CAVITY
UPPER CAVITY
LOWER CAVITY
DIMENSION
Amperes
kW
15,6
3,62
16,1
3,70
16,9
3,84
Electrical Ratings and Maximum Connected Load
@ 120/240 Volts 60 Hz
Amperes
kW
Amperes
kW
31,7
7,32
33.8
7.68
32,5
7,46
33,8
7,68
Before installing or removing, turn power OFF at the service
panel. Lock service panel to prevent power from being turned
ON accidentally.
Securely fasten oven to cabinet using the screws provided.
Failure to do so could result in oven moving or tipping
during use and causing damage to the oven or cabinets or
personal injury.
Know how to disconnect the power to the oven at the circuit
breaker or fuse box in case of an emergency.
Unit is heavy and requires at least two people or proper
equipment to move.
DOUBLE
30"
28 7/16"
(72.2 cm)
24"
(61 cm)
49 3/4"
(126.5 cm)
N/A
1/2"
(1.3 cm) min
Amperes
16,7
Installation Instructions
17,1
17,5
@ 120/208 Volts 60 Hz
Amperes
Amperes
30,9
32.4
31,6
WARNING
32,4
CAUTION
kW
3,45
3,49
ENGLISH
3,54
kW
kW
6,27
6.48
6,39
6,48