Page 2
Owner’s Record Indications for Use/Intended Use The Sony LMD-1951MD LCD Monitor is intended to The model and serial numbers are located at the rear. provide 2D color video displays of images from surgical Record these numbers in the spaces provided below.
Page 3
Consult your dealer. (According to standard EN60601- 1-2 and CISPR11, Class B, Group 1) Front Key inhibit 6. Model LMD-1951MD is a monitor intended for use The setting are locked so in a medical environment to display pictures from that they cannot be cameras or other systems, other than diagnostic X- changed.
Page 4
LMD-1951MD. Guidance and manufacturer’s declaration-electromagnetic emissions The LMD-1951MD is intended for use in the electromagnetic environment specified below. The customer or the user of the LMD-1951MD should assure that it is used in such an environment. Emission test Compliance...
Page 5
Guidance and manufacturer’s declaration - electromagnetic immunity The LMD-1951MD is intended for use in the electromagnetic environment specified below. The customer or the user of the LMD- 1951MD should assure that it is used in such as environment. IEC 60601 test...
Page 6
Guidance and manufacturer’s declaration - electromagnetic immunity The LMD-1951MD is intended for use in the electromagnetic environment specified below. The customer or the user of the LMD- 1951MD should assure that it is used in such as environment. IEC 60601 test...
Page 7
Recommended separation distances between portable and mobile RF communications equipment and the LMD- 1951MD The LMD-1951MD is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the LMD-1951MD can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (Transmitters) and the LMD-1951MD as recommended below, according to the maximum output power of the communications equipment.
Table of Contents Precaution .............. 9 On Safety ............9 On Installation ............ 9 About the LCD Panel ......... 9 On Cleaning ............9 Disposal of the Unit ........... 9 Recommendation to Use more than One Unit ..............10 On Repacking ........... 10 On Fan Error ............
• If the unit is used in a cold place, a residual image may Precaution appear on the screen. This is not a malfunction. When the monitor becomes warm, the screen returns to normal. • If a fixed picture such as a frame of a divided picture On Safety or time code, or a still picture is displayed for a long time, an image may remain on the screen and be...
• Some people may experience discomfort (such as eye strain, fatigue, or nausea) while watching video images. Sony recommends that all viewers take regular breaks while watching video images. The length and frequency of necessary breaks will vary from person to person. You must decide what works best.
The number of the DVI input connectors can be Features increased by installing the optional input adaptor into the optional input port. To view more than SXGA signals when the DVI input is selected, use the cable within 3 m (118 inches) in Compliance with medical safety length.
Page 12
Aspect setting You can set the monitor to 4:3 or 16:9 display mode according to the input signal. Scan function You can select the display from among “NORMAL”, “UNDER”, “OVER”, “FULL”, “ZOOM” and “NATIVE” except the HD15 and DVI input signals. Select language display You can select your language for the display from seven languages - English, French, German, Spanish, Italian,...
Location and Function of Parts and Controls Front Panel a Tally lamp g CHROMA buttons You can check the status of the monitor by the color of Adjusts the color intensity. the tally lamp. Press the + button to increase the color intensity or the – The tally lamp lights in green according to the setting of button to decrease it.
Also, when the fan stops, this button blinks. For details of the function assigned to the function button, see page 31. To display the names of functions assigned to the l USER MEM (user memory) button function buttons Press to load the picture settings saved in the USER When the menu is not displayed and the button is MEMORY menu (on page 34).
*10 The signal cannot operate with PRESET 7 to 9 (see *13 When a BKM-256DD is installed, the number of the page 39). input connector is increased. *11 The signal can only operate with PRESET 1 (see page 39). *14 When a BKM-250TGM is installed, the signal can be input.
Page 17
For details on this connector, refer to the Interface Note Manual for Programmers (saved in the supplied CD- When inputting a video signal with the jitters, etc. the ROM, Japanese and English only.) picture may be disturbed. We recommend using the TBC (time base corrector).
Removing the Rear Connecting the AC Cover Power Cord The rear cover is attached to the terminal at the back. Connect the supplied AC power cord as illustrated. Before you connect cables to the terminal, remove the Two kinds of AC plug holders are supplied with this rear cover as follows.
Next, pull out the DC IN connector from the DC 5V/24V To Use the Optional AC Adaptor IN connector while pressing the lock lever. Plug the AC power cord into the AC IN socket on the AC adaptor (optional). Then, attach the AC plug holder to the AC power cord.
Installing the Input Removing the Adaptor Connector Cover Before installing the input adaptor, disconnect the power When the unit is shipped from the factory, a connector cord. cover is attached to the PARALLEL REMOTE connector and the SERIAL REMOTE connector (RJ- Remove the panel of the optional input port.
Selecting the Default Settings When you turn on the unit for the first time after purchasing it, select the area where you intend to use this unit from among the options. The default setting values for each area Turn on the unit with the (power) switch on the rear panel.
2 If LATIN AMERICA is selected: Selecting the Menu PAL&PAL-N area Language L A T I N A M E R I C A P A L & P A L - N A R E A Argentina A R G E N T I N A P A R A G U A Y Paraguay U R U G U A Y...
The setting items (icons) in the selected menu are Using the Menu displayed in yellow. USER CONFIG – SYSTEM SETTING 1/2 The unit is equipped with an on-screen menu for making M AT R I X : C O M P O N E N T L E V E L : xxxx various adjustments and settings such as picture control, N T S C S E T U P :...
Page 24
The menu icon presently selected is shown in About the memory of the settings yellow and setting items are displayed. The settings are automatically stored in the monitor memory. USER CONFIG – SYSTEM SETTING 1/2 M AT R I X : C O M P O N E N T L E V E L : xxxxx N T S C S E T U P :...
Loading USER MEMORY Adjustment Using the Menus You can load the picture settings saved in the USER MEMORY menu (on page 34). Items The screen menu of this monitor consists of the following items. STATUS (the items indicate the current settings.) For the video input FORMAT COLOR TEMP...
MATRIX For the video input COMPONENT LEVEL NTSC SETUP STATUS 1/2 GAMMA F O R M AT xxxxxxxxx FORMAT DISPLAY xxxxxxxx LANGUAGE C O L O R T E M P POWER SAVING C O M P O N E N T L E V E L xxxxx I/P MODE N T S C S E T U P...
COLOR TEMP/SPACE menu For the video input The COLOR TEMP/SPACE menu is used for adjusting the picture white balance or color space. USER CONTROL 1/3 You need to use the measurement instrument to adjust AU T O C H R O M A / P H A S E the white balance.
Page 28
For the DVI/HD15 input Submenu Setting SUB CONTROL Adjusts finely the adjustment range * The 1/3 menu cannot be adjusted. of the button on the front panel for CONTRAST, BRIGHTNESS, CHROMA and PHASE. USER CONTROL 2/3 • CONTRAST: Adjusts the picture S U B C O N T R O L contrast.
USER CONFIG menu Submenu Setting The USER CONFIG menu is used for setting the PICTURE CONTROL Adjusts to monitor the picture more clearly. system, multi display, function button, computer detect • SIZE H: Adjusts the horizontal and option DVI. size of the picture. The higher the setting, the larger the horizontal size of the USER CONFIG...
Suitable for viewing still logo, you need to write the splash images. logo data. For details, consult your • LINE DOUBLER: The Sony dealer. processing time is shorter. Performs interpolation by repeating each line in the MULTI DISPLAY SETTING data receiving sequence regardless of the field.
Submenu Setting Submenu Setting F1 BUTTON to F4 Assigns the function to the function MULTI DISPLAY Selects ON to display the multi display BUTTON buttons of the front panel and turns the ENABLE and OFF not to display. function on or off. You can assign the function from Notes among SCAN, ASPECT, EXT SYNC,...
COMPONENT t OPTION A-1 t OPTION A-2 t Scan mode image OPTION B-1 t OPTION B-2 t VIDEO WAVE with Input every press of the button (see “SUB INPUT SELECT” on page 31). POSITION Press the button to set the sub display position. The mode switches in the sequence 1 (Bottom left) t 2 (Bottom right) t 3 (Top right) t 4 (Top left) with NORMAL/...
COMPUTER DETECT Submenu Setting EDID STATUS The information downloaded to the BKM-256DD from the EDID of the USER CONFIG COMPUTER DETECT main unit (the monitor) is xxxxx DV I : displayed. xxxxx H D 1 5 : • MODEL: Model name of the monitor •...
USER MEMORY menu Submenu Setting SERIAL REMOTE Selects the mode to be used. • OFF: SERIAL REMOTE does U S E R M E M O RY 1 / 3 not function. x0 1 U S E R 0 1 •...
Page 35
To save the picture setting Press the – button to select “NAME”, then press the ENTER button. Press the + or – button to select the memory number The menu for setting the user name appears. in the USER MEMORY menu, then press the ENTER button.
Troubleshooting Specifications Picture performance This section may help you isolate the cause of a problem and as a result, eliminate the need to contact technical Panel a-Si TFT Active Matrix LCD support. Picture size (diagonal) • The display is colored in green or purple t Select 481.84 mm (19.0 inches) the correct input by pressing RGB or COMPONENT Effective Picture size (H ×...
Page 37
Protection against electric shock: Class I General Protection against harmful ingress of water: Power LCD monitor (LMD-1951MD) Ordinary AC 100-240 V, 50/60 Hz, 0.92 A- Degree of safety in the presence of a flammable 0.40 A anesthetic mixture with air or with oxygen or nitrous DC IN: 24 V 3.5 A 5 V 0.030 A...
Pin number Signal Note Always verify that the unit is operating properly before use. SONY WILL NOT BE LIABLE FOR Available signal formats DAMAGES OF ANY KIND INCLUDING, BUT NOT LIMITED TO, COMPENSATION OR The unit is applicable to the following signal formats.
Page 39
Available HD15/DVI/BKM-256DD input signal format About the preset signal This unit has a preset memory for signals connected to the HD15 and DVI input connectors, and BKM-256DD. When a preset signal is input, the unit automatically detects the signal type and recalls the data for the signal from the preset memory to adjust it to an optimum picture.
Page 43
PRESET 7 (Selected using DVI in the menu) Preset signal [kHz] [Hz] 1422 × 1064 33.75 712 × 480 15.734 704 × 572 15.625 PRESET 8 (Selected using DVI in the menu) Preset signal [kHz] [Hz] 1280 × 1008 33.75 712 ×...
Side Dimensions When an optional stand SU-560 is attached 59.8 101.7 Front When an optional stand SU-560 is attached 455.8 (18) 195 (7 302 (12) Mass Approx. 6.7 kg (14 lb 12 oz) (when the optional stand and the input adaptor 273.5 (10 are not installed) Approx.